User Manual

Wiring:
Strip the wires. Insert wires to terminals and tighten.
ATTENTION: Max torque 150 cNm
Panel cutout (rear side):
Assembled Connector
1. Push insert and chuck into housing.
2. Tighten bushing using open wrench 27 mm,
min. torque 3.5 Nm.
Important: Align the chuck and insert by
positioning the nose into keyway.
[0.394"]
10 mm
N
White
PE
Green
L
Black
DD
1.
2.
25.0
30.0
Ø
3
0
.
0
Ø 3.8
Note: Conductor colors according to color coding of North American cords.
1.
2.
ASSEMBLY INSTRUCTIONS
|
RECEPTACLE
Draft. Nr.: BDA 178 / 3102M1481 Update: 23.12.2011
I I
Data subject to change without prior notice. 2011 NEUTRIK . ALL RIGHTS RESERVED.
®
©
www.neutrik.comwww.neutrik.com
Page 2
ASSEMBLY INSTRUCTION powerCON HC
I
R
NEUTRIK AG LI T: +423 / 237 24 24 F: +423 / 232 53 93
NEUTRIK USA Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 9202
( )
NEUTRIK UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439
NEUTRIK Vertriebs GmbH DE / NL / AT/DK T: +49 8131 / 280 890 F: +49 8131 / 280 830
NEUTRIK France FR T: +33 1 / 4131 6750 F: +33 1 / 4131 0511
NEUTRIK Tokyo Ltd. JP T: +81 3 / 3663 4733 F: +81 3 / 3663 4796
NEUTRIK Hong Kong Ltd. HK T: +852 / 2687 6055 F: +852 / 2687 6052