Install Instructions
Neutra-Safe
®
Condensate Neutralizer
Tube Style
Installation, Operation and Maintenance Manual
Neutrasafe Corporation
neutrasafe.com
421 Page Street, Suite 1
Stoughton, MA 02072
WARNING
• Neutra-Safecondensateneutralizersshouldonlybeinstalledbyaqualiedprofessional.
• Readallinstructionsbeforeinstalling.Performstepsintheordergiven.Failuretocomplycouldresultinsubstantialpropertydamage,
severepersonalinjuryordeath.
• Donotallowuegasestoventthroughcondensateneutralizer.Allcondensatedrainlinesmusthaveagastrap
beforeenteringtheneutralizationunit.Failuretocomplycouldresultinsubstantialpropertydamage,severe
personalinjuryordeath.
• Neutra-Safeneutralizersshouldonlybeconnectedtoacondensateoutletthatisinstalledpertheappliancemanufacturer’sinstructions.
Failuretocomplycouldresultinsubstantialpropertydamage,severepersonalinjuryordeath.
IMPORTANT
• Allpipingshouldbeinaccordancewithrelevantbuildingandmechanicalcodes,aswellasanylocal,stateorfederalregulations.
• Donotconnectmorethanoneappliancetoeachneutralizer.
• Neutralizershouldbeinstalledbelowalltrapsandcondensateoutlets.
• Neutra-Safecondensateneutralizersshouldalwaysbemountedwithaminimumof¼" pitch downwards towards
theoutlet.Itisalsorecommendedthattheinstallermaintainapitchof¼" per foot between the condensate
neutralizeroutletandthepumpordrain.
• Donotusepipedopeonthreadedttings—useonlyTeontape.
• Neutra-SafecondensateneutralizersmayNOTbeinstalledintheverticalposition(ExceptCN2-220V).
• Itisrecommendedthattheneutralizerbeinstalledbeforethecondensatepump.
• Allcondensatetrapsshouldbeprimedbeforecommencingoperationoftheappliance.
• Neutra-SafecondensateneutralizermediasackshouldbereplacedatleastannuallyorwhenpHfallsbelowlocalregulations.
Dimensions In Inches
Model A B BTU/h
CN2-220 14-3/4 1-3/8 220,000
CN2-300C 18-3/4 1-3/8 300,000
CN4B-600C 11-3/4 2-1/2 600,000
CN4B-850C 15-3/4 2-1/2 850,000
CN4B-1200C 17-3/4 2-1/2 1,200,000
CN4B-2000C 26-3/4 2-1/2 2,000,000
B
A
CN2-Models
½" NPT Female
Typical of 2
C
L
B
A
CN4B-Models
¾"NPT Female
Typical of 2
C
L