Installation Instructions

© 2015 UTC Fire & Security Americas Corporation, Inc. All rights reserved. 29
Appendix 1 Advanced Setup
This section contains advanced setup information that may be required depending
on the network environment and feature utilization of the NX-595E.
Output Relay Setup
The NX-595E features two Single Pole Double Throw (SPDT) Form C relays that
can be configured in 3 different modes to support different applications.
The relays are connected to the output terminals with Normally Open and Normally
Closed connections for your convenience.
Use jumpers on J10 and J11 to select the mode suitable for your requirements.
The NX-595E ships with no jumper installed. The Default relay position is in the NC
(normally closed) position.
Jumper J10/J11
Output
C
NC
NO
O
12V +
GND
C
Common C