Installation Instructions

24 © 2015 UTC Fire & Security Americas Corporation, Inc. All rights reserved.
Receiver Account (optional): This field accepts up to 6 Hex digits. If this field is
programmed, all events sent to the receiver will use this account code. If this field is
left blank, the 595E will use the account code that is programmed into the NetworX
panel when reporting events. This field in generally used when PSTN for failover
reporting is enabled and is used to differentiate event delivery via IP or PSTN.
Receiver Supervision Time: The desired time interval in seconds that the
supervision heartbeat is sent to the receiver. A value of 0 disables supervision.
Receiver Number: The receiver number provided by the monitoring station.
Receiver Line Number: The receiver line number provided by the monitoring
station.
Users
Note: The User configuration menu is only accessible when logged in as a Master
User. The default username (Name) is “User 1”. You must use the Master PIN that
is programmed into the NetworX panel to access this menu.
Important: It is strongly recommended that you have the security panel owner
change the default Name (User 1) for the Master User of the system at the time of
installation.