Installation Instructions

© 2015 UTC Fire & Security Americas Corporation, Inc. All rights reserved. 15
Using a NX-182xx touch screen keypad
Step
1.
[MENU]
Press the Menu button
2.
[Settings]
Press the Settings button
3.
[?]-[?]-[?]-[?]
Enter your 4 or 6 digit Programming code
4.
[ Program]
Press the Program button
5.
[ 1 ][ 9 ][ 1 ]
[ENTER]
Connects to device 191 (NX-595E)
6.
[ 9 ][ 1 ][ 0 ]
[ENTER]
Defaults the device, Note: only required once
7.
[ 2 ][ 1 ]
[ENTER]
Access location 21 to retrieve the IP address of the
NX-595E. Scroll through the segments with the
button and record the IP address (e.g. 192.168.1.2)
8.
[Exit]
Press the Exit button. (exiting program mode
automatically enrolls the NX-595E)
Using a Standard Keypad (Icon or LCD)
Step
1.
[ * ] [ 8 ]
Selects Panel and Device programming
2.
[?]-[?]-[?]-[?]
Enter your 4 or 6 digit Programming code
3.
[1][9][1] - [#]
Connects to device 191 (NX-595E)
4.
[9][1][0] - [#]
Defaults the device, Note: only required once
5.
[2][1][#]
To discover the IP address of the NX-595E (Press * to
scroll through each segment of the IP address. Record
the IP address (e.g. 192.168.1.2)
6.
[Exit]
Moves back to step 3
7.
[Exit]
Exits programming (exiting program mode
automatically enrolls the NX-595E)