GE Security NetworX Series TM NX-1348E-ICON Icon keypad User manual g imagination at work
NX-1348E-ICON User manual Page 2 23/07/05
TABLE OF CONTENTS TABLE OF CONTENTS ..................................................................................................................................................................3 INTRODUCTION ...........................................................................................................................................................................4 GLOSSARY OF TERMS ............................................................................................................
INTRODUCTION This manual is furnished to help you understand your security system and become proficient in its operation. All users of your security system should read and follow the instructions in this booklet and, if possible, practice on the keypad control while your professional installer is on site. Failure to do so could result in the security system not working properly. Please keep this booklet in an accessible location for the life of the security system.
GLOSSARY OF TERMS Abort Delay Authority Level Central Station Chime Feature Codes Duress Code Forced Arming Function Code Group Bypass Instant/Delay Master Code Partitioned System Perimeter Quick Arm User Code NX-1348E-ICON User manual An option that allows a delay in reporting to the central station. The level of access an individual has when using an alarm panel. The location where alarm data is sent during an alarm report.
EMERGENCY ACTIVATION KEYS NOTES: You must hold these keys for 2 seconds to activate these functions. Your system may not be programmed for these activation keys. You should press these keys only in an emergency situation that requires response by emergency personnel. If your system is programmed for these functions, the following reports can be sent. Fire Key – This key can activate the fire alarm when pressed for two seconds.
ICON KEYPAD DISPLAY & LED’S Understanding the icons ARMED ICON The armed icon is “on” when the system is armed. The armed icon is “off” when it is disarmed. The armed icon will flash when there has been an alarm during the previous arm cycle. FIRE ICON A steady fire icon means a fire zone has been faulted. A rapidly flashing fire icon means that a fire zone is in a trouble condition. INSTANT ICON The instant icon is “on” when there is no delay on your entry/exit door(s).
LISTEN-IN ICON Listen-in icon is on when an NX-534E audio module is active in listen-in mode. POWER ICON The power icon is on if the mains power is on. It will be off if there is no mains. The power icon will flash if the System has a low battery condition. READY ICON The ready icon is “on” when the system is ready to arm and “flashes” if ready to force arm. NOT READY ICON The not ready icon is on when the system is not ready to arm because of a zone(s) being faulted.
Understanding the LED’s STAY LED The stay led is “on” when all interior (motion detector) zones are bypassed. CHIME LED The chime led is “on” when the chime feature is “on”; “off” otherwise. EXIT LED The exit led is “on” during the exit delay. Please note that the led will flash during the last 10 seconds of the exit delay as a warning that the time is running out. (The user may want to disarm the system if the exit led is flashing in order to prevent an alarm.
KEYPAD FUNCTIONS Arming your system in the “AWAY” mode AWAY is used when the user is away from the premise and wants the interior protected. Step 1 Close all protected doors and windows. • Ready icon will be on or flashing when all protected zones and sensors are secure. NOTE: If any zones are bypassed, a sensor in that zone can be violated without affecting the ready icon. • The security system will not arm if the not ready icon is on or flashing. • If the power icon is off, you have no AC power.
Using the Quick Arm (optional) The Quick Arm feature may be used if it is enabled. Quick Arm will allow the user to arm the security system in the AWAY mode by pressing the [EXIT] key, or arm in the STAY mode by pressing the [STAY] key. This feature is used for ARMING ONLY, and will not disarm the security system. This is ideal for a maid or baby sitter code, etc.
Group bypass By pressing the [BYPASS] key, followed by the [0] key, then the [BYPASS] key again, all zones that are designated as group bypass zones will be bypassed. Press the [BYPASS] key again -or- press the [#] key to exit group bypassing. Unbypassing zones To manually unbypass zones, perform the bypassing procedure on a zone that is already bypassed. The corresponding icon for that zone will go off when unbypassed. NOTE: All zones will automatically be unbypassed each time the system is disarmed.
ASSIGNING USER CODE AUTHORITY LEVELS Assign authority levels to users by following the steps below. Assign user codes before assigning authority levels. Step 1 Press [r]-[6]-[“Master Arm/Disarm Code”]. N Someone changing the authority of another person can only add or remove partition authorization for partitions to which they have access. Step 2 The ready led will flash. Step 3 Enter the 2 digit “user number” to be assigned authority (The ready led is constant and the instant icon will flash).
OTHER KEYPAD FUNCTIONS Setting the keypad tone Step 1 Step 2 Step 3 Press [r]-[0]. Keypad is now in the “Adjust Tone” mode. Pressing the [•] key will make the keypad sounder go to higher tones, pressing the [–] key will make the keypad sounder go to lower tones. When the desired tone is reached, press the [#] key to set this tone and exit from the “Adjust Tone” mode. Change partition (optional) Step 1 Step 2 Step 3 Step 4 Press [r]-[1]. Press a NUMBER key between 1 and 8 to change partitions momentarily.
Set system date Step 1 Step 2 Step 3 Press [r]-[9]-[6]. Enter Code icon will display. Enter a [“Master Code”]. The service icon will appear flashing. Enter the “Day of Week “ 1=Sunday 3=Tuesday 5=Thursday 7=Saturday 2=Monday 4=Wednesday 6=Friday Step 4 Enter the “Month Code”. Must always be two (2) digits. 01 = January 05 = May 09 = September 02 = February 06 = June 10 = October 03 = March 07 = July 11 = November 04 = April 08 = August 12 = December Step 5 Enter the “Day Code”.
SERVICE MENU The service icon will be “on” if the security system requires service. If the service icon is “on”, press [r]-[2] to determine the service condition. If a zone(s) is tampered, the tamper icon will flash and the zone icon(s) will be on. If a zone(s) is troubled, the trouble icon will flash and the zone icon(s) will be on. If the service icon is flashing, one or more zone icon(s) will illuminate indicating what service(s) is required.
KEYPAD CONTROL TONES (BEEPS) A sounder is built into the keypad. If programmed, your system keypad may sound for any of the following reasons: Beeps for all keypresses. Sounds a continuous tone during the Entry delay time. Pulses when a day zone is violated while the system is disarmed. Pulses when a FIRE zone has a trouble condition. Beeps 3 times for trying to arm with the “Not Ready” icon off, if “Force Arming” has not been selected.
SECURITY SYSTEM NOTES Installing/Service Company _________________________________ For Service Call ___________________________________________ Central Station ____________________________________________ Duress Code ____________________ This system is is not partitioned.
ZONE DESCRIPTIONS 01 _________________________ 02 _________________________ 03 _________________________ 04 _________________________ 05 _________________________ 06 _________________________ 07 _________________________ 08 _________________________ 09 _________________________ 10 _________________________ 11 _________________________ 12 _________________________ 13 _________________________ 14 _________________________ 15 _________________________ 16 _________________________ 17 _________________________
www.gesecurity.net EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT ©2005 © GE Security EMEA bvba. All rights reserved. GE Security EMEA bvba grants the right to reprint this manual for internal use only. GE Security EMEA bvba reserves the right to change information without notice.