Operation Manual
NX-10 User Manual 40
Arming
1. Arming in the EN50131 mode differs slightly from arming the
standard system (see page 11) because in this mode the screen
saver is always active. Therefore you have to enter your user code
first to cancel the screen saver, and then to enter your user code
again to arm the system (if arming is allowed). If the system is not
ready, the appropriate message is displayed (see Fault
acknowledging/overriding). When entering code, the number of
code digits entered is displayed in the right lower corner (1, 2, 3,
etc.).
2. The keypad starts to blip and the system begins to arm.
3. Leave the building. The keypad blips increase during the last 10
seconds of the exit time.
4. When the exit time expires, your system is armed and the keypad
sounds continuously for 2 seconds. The status indicator lights red.
Disarming
Disarming process in the EN50131 mode is identical as in the
standard system (see page 11).
Incomplete Exit
If during arming, the Entry/Exit zone (for example, an exit door) is
open at the end of the exit time then the system will not be armed
and the special Exit Error code will be reported. Each Exit Error event
is visible as a fault and it should be acknowledged.
Power supply problems
In case of power supply problems, the following icons are displayed:
Power
Normal
mode
Screensaver
mode
No faults ON ON
AC fault
Battery OK
ON ON Blinking
AC OK
Battery fault
Blinking ON Blinking
AC fault
Battery low
ON ON Blinking
AC OK
Battery low
Blinking ON Blinking
EN50131 Mode