Instructions

User Menus
11. Introduction
In addition to setting and unsetting the system , users 1 - 9 m ay
carry out other operations. These are selected via two user
m enus, "User Menu 1" is available to users 1 - 9 and "User Menu 2"
which is only available to the master user. To access "User Menu
1" enter your passcode and then press [ within 5 seconds.
Pressing ] returns the user to the previous position in the m enu.
12. Bell test
This test allows the user to test the bells, sounders and strobes.
1. Ensure that "User Menu 1 " is selected.
2. Press 1 to select the Bell Test option.
3. The sounders, bells and strobes will operate sequentially for
9 seconds each.
4. Testing m ay be stopped by pressing ] or advanced to next
test by pressing [.
13. Walk Test
This test allows the user to test the function of individual circuits
without creating an alarm . As each circuit is activated its num ber
and status are displayed and the internal sounder generates a
two-tone sound. As m ore circuits are tested they are added in
turn to a scrolling display showing the status of each tested
circuit.
1. Ensure that "User Menu 1 " is selected.
2. Press 2 to select the Walk Test option.
3. Activate circuits in turn by opening doors with contacts and
walking in front of detectors.
4. Check the display to verify which circuits have been tested.
5. On com pletion press ] to quit the Walk Test option.
6
TS700 LED User Operating Instructions
ON 9
Count down display for Bell Test.
1 -
Test com pleted. "User Menu 1"
selected.
NONE
Walk Test selected, but no
circuits have been tested.
05-A
Circuit 05 is now active
05-H
Circuit 05 is now healthy