Owner's manual

NTI XTENDEX USB EXTENDER
5
INTERCONNECTION CABLE WIRING METHOD
The connection cable between the remote and local is terminated with RJ45 connectors and must be wired according to the
EIA/TIA 568 B industry standard. Wiring is per the table and drawing below.
Pin Wire Color Pair Function
1 White/Orange 2 T
2 Orange 2 R
3 White/Green 3 T
4 Blue 1 R
5 White/Blue 1 T
6 Green 3 R
7 White/Brown 4 T
8 Brown 4 R
Figure 5- View looking into RJ45 female
TECHNICAL SPECIFICATIONS
USB to host CPU USB Type B female
USB to device USB Type A female
USB output power 5V, 1.4A for 4 ports (<500mA per port)
Interconnect Cable CAT5/5e Solid/Stranded UTP/STP; CAT6 Solid UTP/STP ; CAT6a Solid UTP;
CAT7 Solid STP EIA/TIA 568 B wiring
Remote Unit Power 100V to 240V at 50 or 60Hz-5VDC/3.0A via AC adapter
Local Unit Power Powered by CPU
Operating temperature 32°F to 122°F (0°C to 50°C)
Storage temperature -20°F to 140°F (-30°C to 60°C)
Operating and Storage Relative Humidity 0 to 90% non-condensing RH
Size (In.) WxDxH 5.1x3.1x1.2
Regulatory Approvals RoHS, CE
Distances for CAT5/CAT5e, CAT6 and CAT7 Cables
CABLE DISTANCE (feet) CABLE DISTANCE (feet)
CAT5/5e
Solid UTP/STP
200
CAT6
Solid UTP/STP
200
CAT5/5e
Stranded
UTP/STP
100
CAT6a
Solid UTP
195
(Distance Includes
10ft patch cable at
each end)
CAT7
Solid STP
200
Longer lengths of CATx cable are not
recommended.
T
1
+
R
2
-
T
3
+
R
4
-
T
5
+
R
6
-
T
7
+
R
8
-
Pair 2 Pair 1
Pair 4
Pair 3