a SERIMUX® Series SERIMUX-TERM-CS-16/8 Terminal Converter with Console Switch Installation and Operation Manual MAN102 Rev Date 8/19/2008
TRADEMARK SERIMUX is a registered trademark of Network Technologies Inc in the U.S. and other countries. COPYRIGHT Copyright © 2003, 2008 by Network Technologies Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202.
TABLE OF CONTENTS INTRODUCTION............................................................................................................................................................. 1 Terminal Converter ...................................................................................................................................................... 1 Console Switch .......................................................................................................................................
Disconnect 2 ports .................................................................................................................................................. 36 Attach or detach a modem...................................................................................................................................... 36 Reset SERIMUX Console Switch to default settings................................................................................................. 36 4. USING THE TERMINAL ..........
TABLE OF FIGURES Figure 1- Mount Switch in a Rack ...................................................................................................................................................... 5 Figure 2- Distinction of connections between TERMINAL and SERIMUX ......................................................................................... 6 Figure 3- Connect serial devices, printer, and power cord..............................................................................................
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH INTRODUCTION The SERIMUX-TERM-CS-x (x=8 or 16) combines a 8 or 16 port Console Switch (SERIMUX) and a VT100/ANSI Terminal Converter (TERMINAL) in a single package controlled by a PS/2 keyboard and VGA monitor. The Console Switch uses menudriven integrated software. The SERIMUX-TERM-CS-16 can control of up to 16 serial devices including servers, switches, routers, and telecom gear.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Console Switch The Console Switch (SERIMUX) includes a text-based menu for easy connection management for administrators. Using a terminal emulator the menu provides a quick means for user serial connection changes and device control. The Console Switch (SERIMUX) is a serial port router that allows links (or connections) between multiple pairs of RS-232 asynchronous serial ports.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH MATERIALS Materials Supplied with the NTI SERIMUX-TERM-CS16 Terminal Converter with Console Switch: IEC Powercord (country specific) DB25M-RJ45F-C Modem Adapter DB9F-RJ45F Serial Adapter +6 RJ45F-T – DB25M Console Adapter DB25F- RJ45F Console Adapter 4- #10-32x3/4” screws and cage nuts Manual CD Materials Not Supplied, but REQUIRED: Serial cable with at least one RJ45 male end for connection to the Console Switch from each device to be connected.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Front and Rear Views of SERIMUX-TERM-CS-16 NTI R SERIMUX R Network T echnolog ies Inc PWR 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Port Discon ESC PORT 6 7 8 9 0 DISCON 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Admin User ADMIN USER 1 2 3 4 5 ENTER 3 2 1 9 NTI R NETWORK TECHNOLOGIES INCORPORATED 10 SERIAL MONITOR 4 11 PRINTER 12 TERMINAL10 BASE T 1275 Danner Dr Tel:330-562-7070 Au
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 1. INSTALLATION 1.1 Rack Mounting Instructions This NTI switch was designed to be directly mounted in a rack and includes a mounting flange to make attachment easy. Install 4 cage nuts (supplied) to the rack in locations that line up with the holes (or slots) in the mounting flange on the NTI switch. Then secure the NTI switch to the rack using four #10-32 x3/4” screws (supplied).
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 1.2 TERMINAL vs. SERIMUX Cable Connections The connectors on the rear of the SERIMUX-TERM-CS-16 are split between those for the TERMINAL connections, and those for the SERIMUX connections (see Figure 2). Terminal Converter (TERMINAL) NTI R MONITOR NETWORK TECHNOLOGIES INCORPORATED SERIAL PRINTER PARALLEL TERMINAL10 BASE T 1275 Danner Dr Tel:330-562-7070 Aurora, OH 44202 Fax:330-562-1999 www.networktechinc.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 1.4 Connect the SERIMUX and TERMINAL to a Network To control the SERIMUX and TERMINAL through a network connected PC, connect a CAT5 Ethernet network cable to the connector marked "TERMINAL-10 BASE T". Then connect the other end of the Ethernet cable to a Local Area Network (LAN) through a 10/100 BaseT switch or hub (see Figure 4).
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 2. GETTING STARTED Introduction This chapter covers basic configuration topics. Included is information on setting up the TERMINAL to control the SERIMUX. 1. Using the instruction under “Setup The TERMINAL” below (or more detailed instruction on page 37), setup the TERMINAL to make connection to the SERIMUX.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH The following lists only what is necessary to connect to SERIMUX. For a complete list of features, see page 37. F2- Genrl SETUP Menu Personality set to Digital Equipment VT-100 or Console ANSI F4- Comm SETUP Menu Baud Rate set to 9600 Ethernet Mode set to OFF to set the communication routing by Serial Port. Data / Stop Bits set to send and receive 8-bits data with one stop bit Xmt Handshake set to None Parity set to none 2.1.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 2. To connect to an attached CPU, enter the number of the port the CPU is connected to and press [ Enter].
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3. USING THE SERIMUX CONSOLE SWITCH The SERIMUX-TERM-CS-16 is controlled using • Terminal Control- using a connected keyboard, VGA Monitor and the built-in TERMINAL • Serial Control- from a "dumb" terminal- locally-connected - through an external modem from a remote location • Keypad Control (reduced set of commands) Terminal Control The TERMINAL built-in to the SERIMUX-TERM-CS-16 can quickly provide access to the Console Switch (see page 8).
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1 Administrator Controls 3.1.1 Login as the administrator 1. 3. 4. The TERMINAL must first be configured (and is typically delivered preconfigured) as described on page 8 under "Getting Started”. Press [ Enter ] on the keyboard, wait three (3) seconds, and the port will open to the "Accessible host list" for "User01", logged in at "Port00". Press [ Esc] to logout, and [Y] to confirm.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1.2 Port List From the Administrator main menu, press [1] to display the Port List. Figure 9- The Port list displays the status of all ports The Port list displays the following information: Column Heading Port Log Con U/H Mdm BaudRate Serial Flow Xon/Xoff Discon DscTime Description Port number and name Index number of the user logged in at the port The number of another port (Pxx) connected to that port .
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH FYI: RE: DscTime ( Disconnect Time) The value shown in the Port list is derived from various sources depending on the type of connection active at the time. - If a user is logged into a port as just a user, the time shown will be the remaining time based on the user's timeout setting.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH From the Port settings menu, the configuration of each port can be viewed and changed.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1.3.1 Port serial settings From the "Port settings" menu, press [5] to display the "Port serial settings" menu. Using this menu, the administrator can adjust the serial settings of each port, or copy the current port serial settings and paste them to another port or to all ports. Figure 12- Port serial settings menu 3.1.3.1.1 Baud rate Any baud rate (serial speed) between 50 bps - 128Kbps can be selected, (except for port 0, between 300 bps - 115.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Note: If a modem is attached to the port, and hardware and/or software flow control is used, the appropriate command may be added to the modem initialization string: Flow control None RTS/CTS (hardware) Xon/Xoff (software) Both disable flow control (not necessary) Command 1 – &K3 &K4 &K6 &K0 Command 2 – \Q3 \Q1 \Q0 Consult your modem user manual or the modem AT command manual to find the suitable command. 3.1.3.1.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1.3.1.10 Copy Port Serial Settings – Press [+] to select the current port as source in a port settings copy-paste process (except port 0). – Then, press [*] to paste the port settings. – Press [Y] to paste the selected port settings to the current port, [A] to paste to all ports, [S] to specify the destination port, or press any other key to cancel. 3.1.3.1.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Display modem settings for different port number Press [>] (greater than symbol) to display the next port (next higher port index) modem settings, or press [<] (less than symbol) to display the previous port modem settings. Press [Esc] or [Space] to return to the "Port settings " menu. 3.1.3.3 Port data buffer From the "Port settings" menu, press [7] to view the port data buffer.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1.4 User List From the administrator main menu, press [4] to display the User list.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1.5 User Settings From the "Administrator main menu", press [5], enter the user index number, then press [Enter].
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Figure 17- Port access list for User 01 3.1.5.1 Port access To quickly grant/deny user access to multiple ports, the use of a dash (-) and/or comma may be used in conjunction with the [1] (to grant) or [0] (to deny) command. i.e. [1] - [1-4,7,9,15] will grant access to ports 1 through 4, 7, 9, and 15, all in one command string 3.1.5.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1.6 Advanced Settings From the "Administrator main menu", press [7] to display the “Advanced settings” menu.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.1.6.2 Firmware From the Advanced settings menu, press [6] to display the Firmware menu. (From Administrator main menu press [7]-[6]) Figure 19- Firmware menu The Firmware menu has three possible functions: Function Description 1. About Firmware Provides information about SERIMUX including revision number, code length, and CRC 2. Load new firmware Initiate firmware upgrade (see Firmware Upgrade on page 31) 3.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Figure 20- The SERIMUX is waiting to save its firmware The terminal program in the CPU connected to Port 1 must be configured for Xmodem protocol. 1. Receive the binary file from the SERIMUX (for example, in HyperTerminal for Windows, use the Transfer -> Receive File command). 2. When saving the file, choose a directory to place the file in and a name that will identify it with the extension " .bin" (i.e. SERIMUX1_8.bin).
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.2. User Controls Users can connect only to accessible ports as defined by the administrator. A list of those ports will be displayed with a successful login. Connection can be made using the TERMINAL, or a serial terminal with an emulator (e.g. Windows HyperTerminal) connected to the SERIMUX at an allowed user port To login, press the [Spacebar] or [Enter] key. Users can login by entering a valid name and password, assigned by the administrator.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.2.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.2.3 Port List screen From the "User main menu", press [3] to display the list of user accessible ports and information about these ports. Only the administrator can change the communication settings.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.2.4 User Terse mode This mode is especially useful when the SERIMUX is directly controlled by external software from a serial console (as a user without administrative privileges), rather than being controlled by a user from a keyboard interface. Entering short command strings performs functions similar to the user main menu commands. A [CR] – [LF] sequence ends every string.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH ¾ Verbose mode Send or type in: [V] [Enter] The answer will be: OK [CR][LF] and the Terse mode will be terminated. The “Accessible host list” or the “User main menu” will be displayed. ¾ User Logout Send or type in: [L] [Enter] The answer will be: OK [CR][LF] With the next login of the same user, Terse mode will resume. 3.2.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 3.3 Firmware Upgrade It may be desired to upgrade the firmware that controls the SERIMUX as soon as improved versions become available. Once the firmware file has been downloaded from www.networktechinc.com to a local CPU, follow these instructions to install it. 1. Using a CPU connected to Port 1, start a terminal program (e.g.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Figure 28- Last confirmation before firmware update 7. Using the terminal program, send the binary firmware file using “1K Xmodem” protocol. Figure 29- File transfer in progress 8. After successful transmission the SERIMUX will automatically restart after few seconds. If not, either power down the RACKMUX and power it back ON (or just press the “System Reset” button (page 30)) and press [Enter[.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH KEYPAD CONTROL Front View of SERIMUX-TERM-CS-16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Port Discon ESC PORT 6 7 8 9 0 DISCON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Admin User ADMIN USER 1 2 3 4 5 ENTER Figure 30- Keypad and LEDs Functions of the Keypad During normal operation, the current administrator port number (if any) is displayed on the front panel.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Disconnect the administrator or a user with administrative privileges Action (from Keypad) 1. Press DISCON 2. 3. Reaction of SERIMUX The LED “Discon” will illuminate. The port 0 LED will be illuminated, the other port LEDs will be OFF. The LED "Admin" will illuminate. If command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate together. They will turn OFF after 30 seconds or when any other key is pressed.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Login user to a port and connect the user port to a host port Action (from Keypad) 1. Press USER 2. 3. 4. 5. 6. 7. Enter the user number Press PORT Enter the user port number Press PORT again Enter the host port number Press ENTER Reaction of SERIMUX The LED “User” will illuminate. The port 0 LED will be illuminated, the other port LEDs will be OFF.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Disconnect 2 ports Action (from Keypad) 1. Press DISCON 2. 3. 4. Press PORT Enter the port number Press ENTER Reaction of SERIMUX The LED “Discon” will illuminate. The port 0 LED will be illuminated, the other port LEDs will be OFF. The corresponding port LED will illuminate, the other port LEDs will be OFF. If command is successful the “Admin”,”Port”,”Discon”.,”User” LEDs will illuminate together.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4. USING THE TERMINAL 4.1 How To Setup The TERMINAL The TERMINAL is compatible with most CPUs and application packages. A menu driven setup system is provided to select and save the settings required by the CPU and application. To control the CPU, or in this case the SERIMUX, a user must be familiar with the requirements of the SERIMUX in order to setup the TERMINAL. 4.1.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4.2 Changing The TERMINAL Operating Parameters To select one of the setup menus shown, press the indicated function key. - The screen for that menu appears with the name highlighted. - The fields at the middle of the screen indicate the parameters that can be changed in that menu. - The top line identifies the keys to press to highlight the parameter fields and change the settings.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Auto Scroll causes the data to scroll up a line when the cursor moves past the last line of the page. Monitor causes the terminal to display symbols for escape sequences and control codes without acting on them (test feature). Status Line sets the top line of the screen as the status line. End of Line Wrap causes the cursor to move to the start of the next line when additional characters are entered at the end of a line.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Comm Mode sets the SERIAL1 port communication mode to full duplex (FDX), block (BLK), half duplex (HDX), or half duplex block (HBLK). Multiple Sessions defines whether an Ethernet connection supports multiple sessions function. ON : indicates the terminal supports multiple sessions. Each session only has one display page. In 80 or 132 column mode, 8 simultaneous sessions are supported. In Econ-80 column mode, 12 simultaneous sessions are supported.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 3- Programmable Keys Enhanced PC-Style Keyboard F1 through F12 (UP ARROW) (DOWN ARROW) (LEFT ARROW) (RIGHT ARROW) BACKSPACE DELETE END Enhanced PC-Style Keyboard ENTER (Both ENTER keys are programmable) ESCAPE HOME INSERT PAGE DOWN PAGE UP PRINT SCREEN TAB F8- Ansbk SET-UP Menu A message of up to 20 characters can be programmed to identify the terminal to the CPU. Enter the message at the cursor position.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH F11- Colr2 Set-up Menu The color functionality differs with emulation. In general VT100, VT220 and ANSI Console work with applications, which control the color directly. The remaining personalities associate colors based on existing monochrome video attributes. This section will define parameter selection based on personality selected. Background = Will determine the color of the background screen under some conditions (16 colors). Normal F.G. \ Normal B.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 5- Color Palettes Palette Display Attribute Normal 0 Reverse (or blank)*1 Intensity*2 Intensity*2 and reverse (or blank)*1 Underline Underline and reverse(or blank)*1 Underline and intensity*2,*3 Underline, intensity, *2 and reverse (or blank)*1 Normal 1 Reverse (or blank)*1 Intensity*2 Intensity*2 and reverse (or blank)*1 Underline Underline and reverse (or blank)*1 Underline and intensity*2,*3 Underline, intensity, *2 and reverse (or blank)*1 Norm
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 5- Color Palettes (Cont'd) Palette Display Attribute Normal 6 Reverse (or blank)*1 Intensity*2 Intensity*2 and reverse (or blank)*1 Underline Underline and reverse (or blank)*1 Underline and intensity*2,*3 Underline, intensity, *2 and reverse (or blank)*1 Normal 7 Reverse (or blank)*1 Intensity*2 Intensity*2 and reverse (or blank) *1 Underline Underline and reverse (or blank)*1 Underline and intensity*2,*3 Underline, intensity, *2 and reverse (or bl
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4.3 Local Keyboard Commands Table 6 lists local keyboard commands in the terminal's native mode.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4.4 TERMINAL Command Guide 4.4.1 Commands Supported in ASCII Personalities Table 8 lists all the ASCII commands recognized by the terminal. The native mode code for the command is given in the second column. (The native mode includes WY-325,WY-120 and WY-60.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 7- Commands Supported in ASCII Personalities (Cont'd) Native Mode ACK mode off ACK mode on Full-duplex mode on Half-duplex mode on Block mode on Block mode off (conversation) Half-duplex block mode on Set Serial 1 port receive handshaking protocol Set Serial 1 port transmit handshaking protocol Set maximum data transmission speed for host port Set Serial 1 port operating parameters Set Serial 2 port operating parameters Enable DTR Serial port 1 Han
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 7- Commands Supported in ASCII Personalities (Cont'd) FUNCTION Native Mode -Program function key definition ESC z fkey sequence DEL ESC Z dir key/fkey sequence DEL ESC Z ~key or ESC Z ~fkey Same ESC ` 8 ESC ` 9 ESC e P ESC e Q ESC ^ 1 ESC ^ 0 ESC ` scroll Same Same Same Same Same Same Same Program key direction and definition Read key direction and definition Wyse WY-50+ ADDS VP A2 ENH Same TVI 910+/925 PC Term ENH Wyse ESC | p1 p2 seq
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 7- Commands Supported in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Display Memory/Split Screen Divide memory into pages ESC w length Display previous page ESC w B or ESC J*8 Display next page ESC w C or ESC K*8 Display page n ESC w page Split screen horizontally ESC x A line (simple split) Split screen horizontally ESC x 1 line (simple split) and clear pages Split screen horizontally ESC x 3
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 7- Commands Supported in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Graphics Characters Graphics mode on Graphics mode off Display graphics character ESC H ESC H ESC H ldraw CTRL B CTRL C Same Same Same ESC $ ESC % ESC $ ESC % Cursor left (backspace) CTRL H Same Same Same Cursor right Cursor up; no scroll Cursor up; scroll (reverse linefeed) Cursor down; no scroll Cursor down; scroll
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 7- Commands Supported in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Editing (Cont'd) Insert line of spaces Delete cursor character Delete cursor line ESC E ESC W ESC R Same Same Same ENH ENH ESC l Same Same Same Same Same Same Clear page to nulls Clear page to spaces Clear page to write-protected spaces Clear unprotected page to spaces ESC * ESC + ESC , Same Same Same ENH ENH ENH Same
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Table 7- Commands Supported in ASCII Personalities (Cont'd) FUNCTION Native Mode Wyse WY-50+ ADDS VP A2 TVI 910+/925 PC Term Print Functions Print formatted page Print formatted unprotected page Print unformatted page Select Parallel printer Select Serial printer Auxiliary print mode off Auxiliary print mode on Transparent print mode off Transparent print mode on Bi-directional mode off Bi-directional mode on Auxiliary receive mode off Auxiliary recei
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4.4.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Variable Values for Table 7 Commands (Cont'd) Foreground Color Black Bue Green Cyan fcolor 1 2 3 4 fcolor 5 6 7 8 Foreground Color Red Magenta Yellow White Function Key F1 F2 F3 F4 F5 F6 field unshifted 0 1 2 3 4 5 field shifted P Q R S T U Function Key F7 F8 F9 F10 F11 F12 field unshifted 6 7 8 9 : ; field shifted V W X Y Z [ Function Key F1 F2 F3 F4 F5 F6 fkey unshifted @ A B C D E fkey shifted ` a b c d e Function Key F7 F8 F9 F10 F11 F12
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Variable Values for Table 7 Commands (Cont'd) length G H I*b Multiple 1xlines 2xlines 4xlines Length of Page Equal to the number of data lines Double the number of data lines Four times the number of data lines *b Available only in WY-50+ personality. Line/Column 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 line/col*c Space ! " # $ % & ' ( ) * + , .
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Variable Values for Table 7 Commands (Cont'd) p1 1 2 3 4 5 Function Key F1 F2 F3 F4 F5 P2 1 2 3 Function Key Remote Local Normal Page 0 1 2 3 4 5 6 Page page 0 page 1 page 2 page 3 page 4 page 5 page 6 Palette 0 1 2 3 Parity 0 1 Color Pallette Palette 0 Palette 1 Palette 2 Palette 3 Parity Bits None Odd p1 6 7 8 9 0 Function Key F6 F7 F8 F8 F10 In the 80 columns mode: There have 4 pages of display memory.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Variable Values for Table 7 Commands (Cont'd) wnd/page 0 1 Window or Page Page 0 or upper window Page 1 or lower window Word 0 1 Data Word 7 bits 8 bits wpca 6 7 A B Write-Protected Display Attribute Reverse*g Dim*g Normal*g Blink on wpca C E F G Write-Protected Display Attribute Invisible on Underline on Reverse on Dim on *g Clears other write-protected attributes wpca1 @ A B C D P Q R S T .
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Supported VT100, VT220 and Console ANSI Commands, Cont'd FUNCTION 132-column display 80-column display Smooth scrolling on Jump scrolling on Reverse screen video on Normal screen video on Line 1 is top of scrolling region Line 1 is top of display area Autowrap on Autowrap off Autorepeat on Autorepeat off Block mode on Block mode off Send form feed after print screen operation No form feed sent after print screen operation Print full screen Print scrolling
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Supported VT100, VT220 and Console ANSI Commands (Cont'd) final A B 0 Final character Designating UK ANSI character set Designating ASCII character set Designating DEC special graphics final < DSCS Final character Designating DEC supplemental(VT220 only) Designating Down-line loadable character set * DSCS can consist of zero, one or two intermediate character and a final character. Intermediate characters are in the range of 2/0 to 2/15.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Supported VT100, VT220 and Console ANSI Commands (Cont'd) Values for “Psn” in table on page 59 Color Psn Psn Color 0 Black 4 Red 1 Blue 5 Magenta 2 Green 6 Brown 3 Cyan 7 White Psn 8 9 10 11 FUNCTION Access alternate graphic set Define erasable character Define non-erasable character Define top half of double-high, double-wide line Define bottom half of double-high, double-wide line Define single-high, single-wide line Define single-high, double-wide li
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Supported VT100, VT220 and Console ANSI Commands (Cont'd) FUNCTION VT100, VT220 Command Console ANSI Editing Functions (Cont'd) Erase erasable characters from start of display to cursor Erase erasable characters in entire display Erase erasable characters from cursor to end of line Erase erasable characters from start of line to cursor Erase erasable characters from entire line Erase n characters beginning at cursor Insert n blank characters beginning
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Supported VT100, VT220 and Console ANSI Commands, Cont'd kc 6 7 8 9 10 37 Unshifted function key F1 F2 F3 F4 F5 F6 Unshifted function key F7 F8 F9 F10 F11 F12 kc 38 39 40 41 43 44 hc Hexadecimal representation of character string assigned to the function key. Note: Multiple function key definitions can be programmed by entering the / parameters for each, separated by semicolons (;).
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Supported VT100, VT220 and Console ANSI Commands (Cont'd) FUNCTION VT100, VT220 Command Console ANSI Auxiliary Keypad Modes Auxiliary keypad numeric mode on Auxiliary keypad application mode on ESC > ESC = Same Same CSI 16 h CSI 16 l CSI ?18 h CSI ?18 l CSI ?19 h CSI ?19 l CSI 0 i or CSI i CSI 2 i CSI 4 i CSI 5 i CSI 6 i CSI 7 i CSI 8 i CSI 9 i CSI ?1 i CSI ?3 i CSI ?4 i CSI ?5 i CSI 1 | CSI 0 | ESC 5 CTRL E CTRL S CTRL Q Same Same Same Same Same S
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Supported VT100, VT220 and Console ANSI Commands, Cont'd FUNCTION VT100, VT220 Request keyboard status report Respond with keyboard language (see table below for values of “Ps”) CSI ? 26 n CSI ? 27; Ps n Values of Ps (above) Keyboard Language Ps 1 U.S. 2 U.K. 3 Danish 4 German 5 French Ps 6 7 8 9 Command Console ANSI Same Same Keyboard Language Spanish Swedish Norwegian Italian *1.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4.6 Using Printer Server via Ethernet Connection Introduction In order to send print jobs to a network-based printer, the Ethernet Print Terminal function in the TERMINAL must be used. To use this function, the Telnet Terminal communication option described on page 1 is available. For this option to work, an Ethernet cable must be connected as described on page 6.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4.6.2 Setup for LPD Follow those steps from step 1 to step 2 described in Basic Setup. The following steps are dependent on the operating system. Please refer to the UNIX administration guide. The following illustrated steps are under BSD system. Step 3. Create a spooling directory Use mkdir command to create a directory for spooling. e.g. mkdir/usr/spool/ETPS1 Step 4.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 4.6.3 LPD printing LPD protocol is built-in to most of the UNIX system. However, detailed implementation of LPD differs among UNIX systems. Please refer to the UNIX administration guide for reference. The following illustrated printing command is under BSD system or System V version. For BSD system: lpr -P For System V version: lp -d This command is to print selected file to the selected printer. e.g.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 5. HARDWARE INFORMATION Introduction This chapter provides information on hardware specifications, pinouts for the Ethernet cable, pinouts for port connectors, and pinouts for the cable adapters. 5.1 Hardware Specifications: TERMINAL Physical Size (In.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 5.3 CPU-to-RACKMUX Ethernet Crossover Cable In order to make a direct connection between a CPU and the ETHERNET connector of the RACKMUX, a crossover cable must be used. The cable is made with CAT5 cable terminated with RJ45 connectors and wired according to the chart below.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 5.6 Cable Adapters The SERIMUX comes with four cable adapters. The following illustrations show cable adapter pin outs. Additional adapters can be purchased from NTI.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH DB25 Female Console Adapter (NTI P/N DB25F-RJ45F) DB25 Female to RJ45 Pin Assignments RJ45 Signal 1 CTS Connected to 2 DSR Connected to 5 DCD 3 RxD Connected to 4 GND Connected to 6 TxD Connected to 7 DTR Connected to 8 RTS Connected to DB25F 4 Signal RTS 20 DTR 2 7 3 6 8 5 TxD GND RxD DCD DSR CTS DB25 Male Modem Adapter (NTI P/N DB25M-RJ45F-C) DB25 Male Modem to RJ45 Pin Assignment RJ45 Signal 1 CTS Connected to 2 DSR Connected to 3 RxD Conn
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 5.
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH Appendix A - SERIMUX Port Characteristics Every port is defined through the following parameters: Description Number Name Type – port 0 Type – except port 0 Baud rate – port 0 Baud rate – except port 0 Data bits per character – port 0 Data bits per character – except port 0 Stop bits – port 0 Stop bits – except port 0 Parity Handshake mode (flow control) Xon character Xoff character Inter-character delay – except port 0 (no delay allowed on port 0) Line
NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH INDEX access to ports, 22 administrator password, 23 ASCII commands, 46 BSD UNIX system, 67 cable adapters, 70 cabling, 69 change administrator password, 23 configure the terminal, 8 connect to SERIMUX.