Model: Z602A ZigBeeTM- Siren Siren Z602A User Manual Copyright©Netvox Technology Co., Ltd. This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
Table of Contents 1.Introduction .................................................................................................................. 3 2. Product Appearance .................................................................................................... 4 3. Product Features ......................................................................................................... 5 4. Operating Instructions...................................................................................
1. Introduction Z602A can be used as a router in ZigBee network. Z602A can be as an alarm in security center (IAS), it can use flashing indicators and alarm sound to alert. There are four different sounds: fire alert, emergency alert, burglar alert, and doorbell sounds. What is ZigBee? ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple network topologies such as point-to-point, point-to-multipoint, and mesh networks.
2.
3. Product Features Compatible with IEEE 802.15.4 Utilizes 2.4GHz ISM band; up to 16 channels DC 12V power supply 4 different sounds (fire, emergency, burglar, and doorbell) Different light flashing Easy installation and configuration Wireless transmission is up to 200 meters linear distance in open field 4. Operating Instructions 4.1. Power On After Z602A is powered on, the network indicator will flash once and make a sound. 4.2. Join The ZigBee Network a.
will stay OFF. In the process of joining, if you press the binding key again, it would turn off permit-join function, and the indicator will stay on. 4.4. Binding Z602A can be bound with Z312 to work as a doorbell. Step1. Press and hold the Binding Key for 3 seconds. Step2. Release the Binding Key when the network indicator flashes once. Step3. Z602A would send out binding request, and Z312 would also need to send out binding request. Step4.
flash and alert according to the time that event triggered. Ex2. If the level of alarm triggered at the same time is high (one of the three), then the priority level of alarm trigger is low (doorbell), then the lower one will not cover other alarm because the priority level of doorbell is low, and the alarm will flash and alarm according to the higher one. No matter what kind of alarm status, when Z602A receives command to stop alarming, it will stop generating sounds.
4.6. Restore To Factory Setting Z602A will keep network information while losing power, including to store the network address that it was assigned etc. If Z602A needs to join a new network, it would need to go back to factory default first. Operation: If you want the device go back to factory default, powered up the device while pressing the setting key, and the status indicator will flash quickly and make the doorbell sound twice.
5.Home Automation Clusters for Z602A 1. End Point(s):0x01: 2. Device ID:IAS Warning Device(0x0403) 3. End Point Cluster ID 4. This lists the attributes of the basic information.
0x0011 PhysicalEnvironment 8-bit Enumeration 0x00 –0xff Read/write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 –0 0x01 Read/write 0x01 M 6.
7. Installation After plug the DC adapter, it should be hung on the wall indoor.
8.
9. Important Maintenance Instructions • Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device dry properly before storing or using. • Do not use or store the device in dusty or dirty areas. • Do not use or store the device in extremely hot temperatures. High temperatures may damage the device or battery.