User's Manual

Clusters of Home Automation for Z311C
Home Automation device feature is defined by the endpoint which contains functional
clusters. Table 1 lists clusters for the endpoint of Z311C. Zone Type attribute value is
0x0015 as Contact switch.
When the magnetic contact piece is moving away from the body of the device or a
detected glass-break, Z311C sends out Zone status attribute as Alarm1 having the
attribute value of 1 for alarmed.
When the magnetic contact piece is close or attached to it, Z311C sends out Zone status
attribute as Alarm1 having the attribute value of 0 for not alarmed.
Table 1: Clusters supported by the Z311C endpoint 0x01
Cluster ID for Z311C
Server side Client side
EP 0x01 (Device ID: IAS Zone(0x0402) )
Basic(0x0000) None
Power configuration(0x0001)
Identify(0x0003)
IAS zone ( 0x0500)