5-5. Battery
When the operating voltage is lower than 2.4V, will send a low-power report to the ZigBee network.
5-6. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Remove the batteries to power off .
Step2. Press and hold the Reset Key, then power on to complete the restore.
6. Home Automation Clusters for
A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A
simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves. This table
lists the clusters which are supported by .
1.End Point(s) 0x01
2.Device IDDimmer Switch (0x0104)
3.EndPoint Cluster ID
Attributes of the Basic
Cluster
Information
Identifier Name Type Range Access Default Mandatory /
Optional
0x0000 ZCLVersion Unsigned
8-bit integer
0x00
0xff
Read only 03 M
Server side Client side
Basic (0x0000)
Power Configuration(0x0001)
Identify (0x0003)
On/off switch configuration(0x0007)
On/off0x0006
Commissioning0x0015
Level control0x0008
Poll Control(0x0020)
Diagnostics(0x0B05)
BLZ-US-01
BLZ-US-01
BLZ-US-01
BLZ-US-01
BLZ-US-01
BLZ-US-01