User's Manual

16
Report setting interval table
Min Interval
(Unit:second)
Max Interval
(Unit:second)
Reportable
Change
Change rate Reportable
Change
Change rate
Reportable Change
1-65534 1-65534
0
To report per Minimum
interval
To report per Maximum
interval
0
To report per Minimum
interval
To report per Minimum
interval
0 1-65534
0 To report instantly
To report per Maximum
interval
0 To report per second To report per second
1-65534 0
0
To report per Minimum
interval
No report
0
To report per Minimum
interval
To report per Minimum
interval
0 0
0 To report instantly No report
0 To report per second To report per second
Any 65535 Any Stop reporting
65535 Any Any Stop reporting
Note(1)It is not suggested to set:
Min Interval =0,
Reportable Change=0,
Z809A will report very densely to block up the network.
(2)
Yellow areas are not suggested.
(3) Reportable change unit: V.
(4) Once binding completes, will send data report to bind device. Default min. and max. is
3600 seconds. While detects low voltage, it will send warning.
(5) Low voltage waning mode 0X003E and voltage ID 0X0020 share the same cluster 0x0001.
Once binding with cluster 0x0001, there is no need to bind 0X003E and 0X0020 again.
BLZ-US-01
BLZ-US-01