User manual
3
GB
Mounting:
• Use ergo
®
4052 or Loctite
®
to seal all threads.
• Remove the bolt (2) and the L-Fitting (3). Mount the 3/2 way air valve (6).
Connect the valve and the housing PKL 135 with set ST (1).
• Required air pressure for use of set ST:
PKL 135/4 = 4,2 bar PKL 135/6 = 5,9 bar
• Filter-lubricator-unit ¼” (4): Always required
• 2/2 way valve (7): Starts interval knocking
• Throttle (8): Regulation of knocking frequency
• 3/2 way valve (5): Start of one knock (without ST)
without ST with ST
NetterVibration