User manual
Technical data
8
The noise level of the PKL may exceed 80 dB(A) (single noise incident).
Depending on the impact sequence the continuous noise level is below
this value.
The PKL should be preferably mounted with the EE kit. The noise reduc-
tion is about ca. 5 dB(A) (single noise incident).
The sound emitted by the PKL can be dampened by hoods (on request).
This is only worthwhile if the impacted sheet metal is also insulated (e.g.
by heat insulation material).
PKL 190 PKL 450 PKL 740
Type:
PKL...
A
[mm]
B
[mm]
C
[mm]
Ø D
[mm]
E
[mm]
F
G
[mm]
H
[mm]
H*
[mm]
190 38.0 111 15 9.0 - G 1/8,
NW 6 × 1
90.0 163.5 169.5
450 73.5 126 14 13.0 - 90.0 192.0 200.0
740 90.0 140 15 13.0 50 100.0 238.5 248.5
*) with EE kit
Noise level
Dimensions
PKL
190 /
450 /
740