User manual

Maintenance and servicing
22
8 Maintenance and servicing
IMPORTANT
Observe the safety instructions in Ch. Safety, page 5.
Maintenance of the PKL must be carried out as follows:
Interval Action
After one hour of opera-
tion after initial commis-
sioning
Check fastening and locking screws.
Check hose screw connections and hose connections and
retighten, if necessary.
Monthly Check fastening and locking screws.
Check hose screw connections and hose connections and
retighten, if necessary.
Check hose supply connections for permeability and kinks. If
necessary, clean and remove kinks.
Check the function of the silencer.
Check impact effect.
Ensure that mist lubricator operates according to regulations
(content decreases? number of drops/h? Refill oil.
Empty the filter of the maintenance unit if necessary, clean
the filter insert (wash out) and replace if necessary.
At the latest after a total
of 500,000 strokes
Carry out the general overhaul, in which all wear parts must
be replaced.
In the course of its service life, a film can form due to wear, which impairs
functioning. If loss in performance or standstill is noticed, proceed as fol-
lows:
1. Remove piston.
2. Clean piston.
3. Replace guide ring and piston seal, if necessary.
4. Reinsert piston.
Special tools are needed for inserting piston, guide rings and piston seal
(available on request).
The maintenance intervals depend essentially on the service life, how
clean the drive medium is and the lubricant used. Unfiltered compressed
air leads to high wear, blockage of the silencer and complete breakdown
of the PKL.
Maintenance, repair and general overhaul of the PKL may alternatively be
performed by NetterVibration.
Safety
instructions
Maintenance
plan
Cleaning
Maintenance
intervals
Implementa-
tion by Netter