User manual
Installation
20
Example: PKL 2100
1
Ball valve
2
Maintenance unit
3
Opening cylinder
4
Non-return throttle valve
If the PKL
is equipped with an
ST
kit, then it can be coupled
with another function without a
control or a pulse generator.
The adjacent illustration shows
the coupling with an opening
cylinder (3) of a weighing con-
tainer.
The PKL
is now not actuated.
When opened, it strikes at the
set number of cycles on the
non-return throttle valve
(4), as
long as the flap is open.
Check that the following steps have been carried out:
Permissible ambient temperatures observed?
Fastening device mounted (±0.3 mm flatness)?
PKL mounted with NBS fastening set?
PKL 2100, PKL 5000 and PKL 10000
mounted with damper
ring (flange)?
Ball valve, maintenance unit (filter, regulator, mist lubricator),
valve and supply line mounted?
Information on hose length and nominal width observed?
Fastening screws and hose lines secured with an adhesive
(e.g. Loctite®), if required?
PKL
in critical assembly situations secured against falling by
means of a safety cable?
Installation
with coupling
to other func-
tions
Checklist
installation