User Manual

6
Physical
Unit Dimension (mm)
Net Weight (Kg)
Environment
Operating Temperature
Humidity
Noise Level
253 x 146 x 45mm
0.7kg
0° - 40° C
20% - 90%
Less than 40dB
* Product specications are subject to change without notice.
* To ensure the safety of transportation, the battery is not fully charged
when leaving the factory. Please charge before use.
8. Troubleshooting
Issue / Error Possible Explanation/Solution
Status LED is RED
This is not an error or issue. This means that the AC/Mains
power is off and the connected devices are running from the UPS
battery power.
25% Battery capacity
indicator LED is ashing
This indicates that the remaining battery capacity is very low
(below 25%) and the battery power will run out soon if the AC/
Mains power is not restored.
Neither the 9V nor the
12V LED is on
This is not an error or issue. This only means that there is no
device with a load connected to the Yellow 9V/12V Output port
on the UPS. 1 of these 2 LEDs will light up only when a device
is connected to this port. Which LED to light up will depend on
which voltage the Selector switch is set to.
Status LED is ashing
YELLOW
The maximum Output power of the UPS is exceeded and the
USB ports have been disabled as result. To resolve this, remove
excess load by removing/disconnecting some of the connected
devices.
USB Ports are not
working
Conrm if the STATUS LED is ashing Yellow. If so; the maximum
Output power of the UPS is exceeded and the USB ports have
been disabled as a result. To resolve this, remove excess load by
removing/disconnecting some of the connected devices.
All power indicator
LEDs ashing
The maximum Output power of the UPS is exceeded and the
disabling the USB ports did not resolve/reduce the load enough.
To resolve this, remove excess load by removing/disconnecting
some of the connected devices.