Operation Manual

Optimize Performance With Quality of Service
36
ProSAFE 10-Gigabit Ethernet Web Managed Switch
If you do not know the IP address of the switch, see Access the Switch Using a Web
Browser on page 14.
The login window opens.
4. Enter the switch’s password in the password field.
The switch’s default password is password.
The Switch Information page displays.
5. Select QoS > Rate Limit.
6. Set the ingress (incoming) and egress (outgoing) traffic rates by doing the following:
a. Select one or more ports.
b. In the Ingress Rate menu, select the maximum rate.
You can set a rate from 32 to 4096 Mbps. By default, no limit is set.
c. In the Egress Rate menu, select the maximum rate.
You can set a rate from 32 to 4096 Mbit/s. By default, no limit is set.
d. Click the Apply button.
Your settings are saved.
7. To set different rates for one or more other ports, repeat Step 6.
Use the ProSAFE Plus Utility to Set Up Rate Limiting
To set up rate limiting:
1. Connect your computer to the same network as the switch.
You can use a WiFi or wired network connection, or connect directly to a switch that is
off-network using an Ethernet cable.
2. Double-click the ProSAFE Plus Utility icon.
The Switch Selection page displays a list of Web Managed switches that it discovers on
the local network.
3. Select the switch.