81
M6100 Web Management User Guide
3. Select the Management Status. Indicates whether the selected switch is the management
unit, or a normal chassis member, or on standby.
4. Click the Apply button.
The system prompts the administrator to confirm the management
move. Upon administrator confirmation, the entire chassis, including all interfaces in the
chassis, is unconfigured and reconfigured with the configuration on the new Primary
Management Unit. Configuration changes take place immediately.
5. Click the Cancel button to cancel the configuration on the screen.
The data on the
screen is reset to the latest value of the switch.
6. Click Update to update the page with the latest information on the switch.
7. After the reload is complete, all chassis management capability must be performed on
the new Primary Management Unit.
The following table describes the non-configurable fields on the Chassis Configuration
page.
Table 37. Chassis Configuration
Field Description
Hardware Management
Preference
The hardware management preference of the blade. The hardware
management preference can be disabled or unassigned.
Standby Status Identifies the switch that is configured as the Standby Unit. The
possible values are:
• Cfg Standby. Indicates that the blade is configured as the
Standby blade.
The blade configured as the Standby blade
becomes the supervisor if the current supervisor fails.
• Opr Standby. Indicates that this blade is operating as the
Standby
.
Switch Status Displays the status of the selected unit. The possible values are:
• OK
• Unsupported
• Code Mismatch
• Config Mismatch
• Not Present
• SDM Mismatch
• Updating Code
The following table describes the non-configurable fields in the Basic Chassis Status.
Table 38. Basic Chassis Status
Field Description
Unit ID The Unit ID of the specific blade.
Switch Description The description for the blade that can be configured by the user.