Configuring System Information
93
M6100 Web Management User Guide
Table 50. NSF Summary
Field Description
Operational Status Indicates whether NSF is enabled on the chassis. NSF is enabled
by default.
Last Startup Reason The type of activation that caused the software to start the last
time.
The possible values are:
• Power On — The switch is rebooted. This could have been
caused by a power cycle or by an administrative Reload
command.
• Cold Admin
Move — The system resets all hardware tables
without a reboot and the application begins from a
pre-initialized state, but no data is retained from before the
failover
.
• W
arm Admin Move — The administrator issued a command for
the standby manager to take over.
• Auto W
arm — The primary management card restarted due to
a failure, and the system executed a nonstop forwarding
failover.
• Auto Cold — The system switched from the active manager to
the backup manager and was unable to maintain user data
traf
fic. This is usually caused by multiple failures occurring
close together.
Time Since Last Restart Time since the current management card because the active
management card. For backup manager
, the value is set to
0d:00:00:00.
Restart In Progress Indicates whether a restart is in progress. A restart is not
considered complete until all hardware tables have been fully
reconciled.
Warm Restart Ready Indicates whether the initial full checkpoint has finished.
Copy of Running Configuration to Backup Unit
Status Status of copying running configuration to backup blades.
Backup Configuration Age Indicates the time since the running configuration was last copied
to the backup blade.
Time Until Next Backup Indicates the number of seconds until the running configuration will
be copied to the backup blade.
NSF Support on Unit
Unit ID Displays the slot number for the blade.
NSF Support Displays whether the switch supports the Non-Stop Forwarding
(NSF) feature.
3. Click Initiate Failover to cause the supervisor unit to fail over to the backup blade.
4. Click Update to update the page with the latest information on the switch.