The following table describes the non-configurable Backplane-port packet-path data that is
displayed.
Table 42. Backplane-port Packet-path
Field Description
Direction Displays the path direction.
Packet-path Displays the packet path.
Click Update to update the page with the latest information on the switch.
Chassis Power Configuration
To configure chassis power:
Figure 16. Chassis Power Configuration
1. Click System > Chassis > Advanced > Chassis Power Configuration.
2. In the Power Module Redundancy field, specify whether power redundancy mode is
Enabled or Disabled.
3. Click the Apply button to apply the power redundancy mode.
4. Click Update to update the page with the latest information on the switch.
To configure system power:
1. Click System > Chassis >
Advanced > Chassis Power Configuration.
2. In the System Power field, specify the power reserved for system, excluding PoE power
.
This provides a way to reserve power for blades. The remaining power can be used by a
PoE sub system. System Power should be less than or equal to 2550W
. Use 0 to reset
System Power to defaults.
3. Click the Apply button to apply the system power
.