Configuring System Information
49
M6100 Web Management User Guide
Configure Green Ethernet Local Device Details
To configure the green Ethernet local device information:
1. Select the Interface for which data is to be displayed or configured.
2. Use the Energy Detect
Admin Mode selection to enable or disable this option on the port.
With energy detect mode enabled, when the port link is down, the PHY will automatically go
down for short period of time, and then wakes up to check link pulses. This will allow
performing auto-negotiation and saving power consumption when no link partner is present.
The Default value is Disabled.
3. Use the Short Reach
Admin Mode selection to enable or disable this option on the port.
With short reach mode enabled, PHY is forced to operate in low power mode irrespective of
the cable length. The Default value is Disabled.
4. Use the EEE Admin
Mode selection to enable or disable this option on the port. With EEE
mode enabled, Port transitions to Low power Mode during Link Idle condition. The Default
value is Disabled.