RFC 2465 (IPV6 MIB)
The following tables, groups, and variables are supported in this MIB.
portCopyDirection This object affects the way traffic is
copied from a switch source port, for the
indicated port copy operation. If this
object has the value copyRxOnly (1)',
then only traffic received on the
indicated source port will be copied to
the indicated destination port. If this
object has the value 'copyTxOnly (2)',
then only traffic transmitted out the
indicated source port will be copied to
the indicated destination port. If this
object has the value 'copyBoth (3)', then
all traffic received or transmitted on the
indicated source port will be copied to
the indicated destination port.
The creation and deletion of instances of
this object is controlled by the
portCopyRowStatus object. Note that
there is no guarantee that changes in
the value of this object performed while
the associated portCopyRowStatus
object is equal to active will not cause
traffic discontinuities in the packet.
portCopyStatus Defines the status of the port copy entry.
In order to configure a source to
destination portCopy relationship, both
source and destination interfaces MUST
be present as an ifEntry in the ifTable
and their respective ifAdminStatus and
ifOperStatus values MUST be equal to
'up(1)'. If the value of any of those two
objects changes after the portCopyEntry
is activated, portCopyStatus will
transition to 'notReady (3)'.
The capability of an interface to be
source or destination of a port copy
operation is described by the
'copySourcePort (0)' and 'copyDestPort
(1)' bits in dataSourceCopyCaps. Those
bits SHOULD be appropriately set by the
agent, in order to allow for a
portCopyEntry to be created.
smonPrioStatsControlTable
Not supported due to hardware
limitations.
smonPrioStatsTable