Chapter 30. vMAN (PBN) 8800 Chassis Switch
Figure 99. Sample vMAN Configuration on NETGEAR 8810 Switch
The vMAN is configured from the building to port 1, slot 3 on the NETGEAR 8810 switch and
from port 2, slot 3 on the NETGEAR switch to the NETGEAR 8806 switch:
enable jumbo frames
create vman vman_tunnel_1
configure vman vman_tunnel_1 tag 100
configure vman vman_tunnel_1 add port 3:1 untagged
configure vman vman_tunnel_1 add port 3:2 tagged
enable dot1p examination port 3:2
The following example configuration demonstrates configuring IP multicast routing between
vMANs and VLANs (when vMAN traffic is not double-tagged) on the NETGEAR 8800
switches. Using this configuration you can use a common uplink to carry both VLAN and
vMAN traffic and to provide multicast services from a vMAN through a separate VLAN (notice
that port 1:1 is in both a VLAN and a vMAN):
enable jumbo-frame ports all
configure vman ethertype 0x8100
create vlan mc_vlan
configure vlan mc_vlan tag 77
create vman vman1
configure vman vman1 tag 88
configure vlan vman1 ipaddress 10.0.0.1/24
configure vlan mc_vlan ipaddress 11.0.0.1/24
enable ipforwarding vman1
enable ipforwarding mc_vlan
enable ipmcforwarding vman1
enable ipmcforwarding mc_vlan
configure vlan mc_vlan add port 1:1 tag
configure vman vman1 add port 1:1 tag
configure vman vman1 add port 2:1, 2:2, 2:3