Owner's Manual

536 | Chapter 18. STP
NETGEAR 8800 User Manual
Configured the mode of operation for the STPD
Configured the STP ports
Enabled STPD
The following example shows how to configure STPD BPDU tunneling on devices running
XCM8800:
Switch A
enable ignore-bpdu vlan v1
enable ignore-bpdu vlan v2
enable ignore-bpdu vlan v3
configure vlan v1 add ports 1:1,2:1 tagged stpd s1
configure vlan v2 add ports 1:2,2:1 tagged stpd s2
configure vlan v3 add ports 1:3,2:1 tagged stpd s3
Switch B
enable ignore-bpdu vlan v1
enable ignore-bpdu vlan v2
configure vlan v1 add ports 1:1,2:1 tagged stpd s1
configure vlan v2 add ports 1:2,2:1 tagged stpd s2
Switch C
enable ignore-bpdu vlan v1
enable ignore-bpdu vlan v3
configure vlan v1 add ports 1:1,2:1 tagged stpd s1
configure vlan v3 add ports 1:3,2:1 tagged stpd s3
The following example shows how to configure STPD BPDU tunneling on devices running
XCM8800:
Switch A
configure vlan v1 add ports 1:1,2:1 tagged
configure vlan v2 add ports 1:2,2:1 tagged
configure vlan v3 add ports 1:3,2:1 tagged
configure stpd s1 add vlan v1 ports 1:1
configure stpd s2 add vlan v2 ports 1:2
configure stpd s3 add vlan v3 ports 1:3
disable s1
disable s2
disable s3
Switch B
configure vlan v1 add ports 1:1,2:1 tagged
configure vlan v2 add ports 1:2,2:1 tagged
configure stpd s1 add vlan v1 ports 1:1