Chapter 8. Status Monitoring and Statistics | 211
NETGEAR 8800 User Manual
Download %: 100
Flags: M E
Restart count: 0 (limit 5)
Serial number: 800424-00-02 1104G-02442
Hw Module Type: XCM8808X
SW Version: 12.4.3.5
SW Build: v1243b5-patch1-3
Configured Type: XCM8808X
Ports available: 8
Recovery Mode: Reset
Flags : M - Backplane link to Master is Active
B - Backplane link to Backup is also Active
D - Slot Disabled, S - Slot Secured
I - Insufficient Power (refer to "show power budget")
Clearing the Shutdown State
If you configure one or more modules to shut down upon detecting a hardware fault, and the
switch enters the shutdown state, you must explicitly clear the shutdown state and reset the
affected modules for the switch to become functional. To clear the shutdown state, use the
following command:
clear sys-recovery-level
The switch prompts you to confirm this action. The following is a sample confirmation
message:
Are you sure you want to clear sys-recovery-level? (y/n)
Enter y to confirm this action and clear the shutdown state. Enter n or press [Enter] to cancel
this action.
After using the clear sys-recovery-level command, you must reset each affected module.
If you configured only a few I/O modules to shutdown, reset each affected I/O module as
follows:
1. Disable the slot using the disable slot <slot> command.
2. Re-enable the slot using the enable slot <slot> command.
Note: You must complete this procedure for each module that enters the
shutdown state.
If you configured all I/O modules or one or more MSM/MMs to shutdown, use the reboot
command to reboot the switch and reset all affected I/O modules.