Owner's Manual
Chapter 7. PoE | 189
NETGEAR 8800 User Manual
• Delivering
• Faulted
• Disconnected
• Other
• Denied
• PD’s power class—Displays the class type of the connected PD:
• “-----”: disabled or searching
• “class0”: class 0 device
• “class1”: class 1 device
• “class2”: class 2 device
• “class3”: class 3 device
• “class4”: class 4 device
• Volts—Displays the measured voltage. A value from 0 to 2 is valid for ports that are in a
searching or discovered state.
• Curr—Displays the measured current, in milliamperes, drawn by the PD.
• Power—Displays the measured power, in watts, supplied to the PD.
• Fault—Displays the fault value:
• None
• UV/OV fault
• UV/OV spike
• Over current
• Overload
• Undefined
• Underload
• HW fault
• Discovery resistance fail
• Operator limit violation
• Disconnect
• Discovery resistance, A2D failure
• Classify, A2D failure
• Sample, A2D failure
• Device fault, A2D failure
• Force on error
The detail command lists all inline power information for the selected ports. Detail output
displays the following information:
• Configured Admin State
• Inline Power State