Owner's Manual

Chapter 7. PoE | 185
NETGEAR 8800 User Manual
Slot-6 XCM8848T(P) XCM8848T Operational 48 MB
MSM-A XCM88S1 Operational 0
MSM-B XCM88S1 Operational 0
Flags : M - Backplane link to Master is Active
B - Backplane link to Backup is also Active
D - Slot Disabled
I - Insufficient Power (refer to "show power budget")
You can expect to see the following log messages generated by the system after you
have attached the card:
<Warn:HAL.Card.Warning> MSM-A: Powering on mismatch card - cfg: XCM8848T actual:
XCM8848T(P)
<Warn:HAL.Card.Warning> MSM-B: Powering on mismatch card - cfg: XCM8848T actual:
XCM8848T(P)
4. Change the slot module type to include POE by executing the command
configure slot 4 module XCM8848T (PoE).
Note: You must configure the slot as (PoE) before the power feature is
accessible or enabled.
The following output displays the results of the show slot command after this command
has been executed:
XCM8806.2 # show slot
Slots Type Configured State Ports Flags
-------------------------------------------------------------------------------
Slot-1 XCM8824F XCM8824F Operational 24 MB
Slot-2 XCM8824F Empty 24
Slot-3 XCM888F XCM888F Operational 8 MB
Slot-4 Empty 0
Slot-5 XCM8808X XCM8808X Operational 8 MB
Slot-6 XCM8848T(P) XCM8848T(P) Operational 48 MB
MSM-A XCM88S1 Operational 0
MSM-B XCM88S1 Operational 0
Flags : M - Backplane link to Master is Active
B - Backplane link to Backup is also Active
D - Slot Disabled
I - Insufficient Power (refer to "show power budget")
5. Save the configuration by executing the command save configuration.