Reference Manual
Configure the System and Network Settings and Register the Licenses
112
ProSAFE Wireless Controller WC9500
Configure Alarm Notification Settings
You can classify certain events as critical, major, normal, or minor. Some events you can
classify only as critical or major. For example, on the RF Management screen, you can
specify whether a coverage hole must be classified as critical or major (see Configure Radio
Frequency Management for the Basic Profile Group on page 192).
To configure alarm actions:
1. Open a web browser. In the browser’
s address field, type the wireless controller’s IP
address.
By default, the IP address is 192.168.0.250.
The wireless controller’s login screen displays.
2. Enter your user name and password.
If you did not yet personalize your user name and password, enter admin for the user
name and password for the password, both in lowercase letters.
3. Click the Login button.
The wireless controller’s web management interface opens and displays the Summary
screen.
4. Select Configuration
> System
> Alerts/Logs > Alarms.
The Alarm Actions screen displays:
5. For each alarm severity (Minor, Normal, Major, and Critical), select the desired action from
its corresponding Action menu.
• No Action. When the alarm occurs, no action is taken.
• Add To Syslog. When the alarm occurs, the wireless controller adds an entry to the
syslog.
• Send Email. When the alarm occurs, the wireless controller sends an email.