User Manual
Table Of Contents
- S3300 Smart Managed Pro Switch
- Contents
- 1. Getting Started
- Getting Started with the NETGEAR Switch
- Switch Management Interface
- Connect the Switch to the Network
- Discover a Switch in a Network with a DHCP Server
- Discover a Switch in a Network without a DHCP Server
- Configure the Network Settings on the Administrative System
- Access the Management Interface from a Web Browser
- Understand the User Interfaces
- Interface Naming Convention
- Configuring Interface Settings
- Online Help
- Registration
- 2. Configure System Information
- 3. Configuring Switching
- 4. Configuring Routing
- 5. Configuring Quality of Service
- 6. Managing Device Security
- 7. Maintenance
- 8. Monitoring the System
- A. Configuration Examples
- B. Hardware Specifications and Default Values
Configure System Information
94
S3300 Smart Managed Pro Switch
Status Operational status of the port PD detection. Possible values are:
• Disabled. Indicates that no power is being delivered.
• Delivering Power. Indicates that power is being drawn by the
device.
• Fault. Indicates a problem with the power.
• Other Fault. Indicates that the port is idle due to an error
condition.
• Requesting Power. Indicates that the port is requesting power.
• Searching. Indicates that the port is not in one of the other
states in this list.
• Test. Indicates that the port is in Test mode.
Fault Status Describes the error description when the PSE port is in fault status.
Possible values are:
• No Error. Specifies that the PSE port is not in any error state
• MPS Absent. Specifies that the PSE port has detected an
absence of main power supply.
• Short. Specifies that the PSE port has detected a short circuit
condition.
• Overload. Specifies that the PD connected to the PSE port has
tried to provide more power than is permissible by the
hardware.
• Power Denied. Specifies that the PSE port has been denied
power because of a shortage of power, or due to
administrative action.
Table 32. PoE Port Configuration Non-Configurable Data (continued)
Field Description