User Manual
Table Of Contents
- S3300 Smart Managed Pro Switch
- Contents
- 1. Getting Started
- Getting Started with the NETGEAR Switch
- Switch Management Interface
- Connect the Switch to the Network
- Discover a Switch in a Network with a DHCP Server
- Discover a Switch in a Network without a DHCP Server
- Configure the Network Settings on the Administrative System
- Access the Management Interface from a Web Browser
- Understand the User Interfaces
- Interface Naming Convention
- Configuring Interface Settings
- Online Help
- Registration
- 2. Configure System Information
- 3. Configuring Switching
- 4. Configuring Routing
- 5. Configuring Quality of Service
- 6. Managing Device Security
- 7. Maintenance
- 8. Monitoring the System
- A. Configuration Examples
- B. Hardware Specifications and Default Values
Maintenance
311
S3300 Smart Managed Pro Switch
Figure 114. Traceroute IPv6
2. Use IPv6 Address/Hostname to enter the IPv6 address or Hostname of the station to
which the switch should find a path. The initial value is blank. The IPv6 Address or
Hostname you enter is not retained across a power cycle.
3. Ente
r the Probes Per Hop. Specify the number of times each hop should be probed. The
default value is 3. The range is 1 to 10.
4. Ente
r the Maximum TTL maximum time-to-live for a packet in number of hops for the
destination. The default value is 30. The range is 1 to 255. The MaxTTL you enter is not
retained across a power cycle.
5. Ente
r the Initial TTL initial time-to-live for a packet in number of hops. The default value
is 1. The range is 1 to 255. The InitTTL you enter is not retained across a power cycle.
6. Ente
r the Maximum Failures allowed in the session. The default value is 5. The range is 1
to 255. The MaxFail you enter is not retained across a power cycle.
7. Interval
(secs) - Enter the number of seconds between probes. The default value is 3.
The range is 1 to 60. The Interval you enter is not retained across a power cycle.
8. Ente
r the UDP Destination Port in the probe packets. The default value is 33434. The range
is 1- 65535. The port you enter is not retained across a power cycle.
9. Ente
r the Size of the probe packets. The default value is 0. The range is 0 to 39936. The
Size you enter is not retained across a power cycle.
• Source. Select the
source type from which the packet is sent:
- None. The source is the I
P address of the default outgoing interface.
- I
P address. The source is an IP address that you specify. If you select this option,
the IP Address field appears. Specify the source IP address of the probe packet in
the IP address field.