User Manual
Table Of Contents
- S3300 Smart Managed Pro Switch
- Contents
- 1. Getting Started
- Getting Started with the NETGEAR Switch
- Switch Management Interface
- Connect the Switch to the Network
- Discover a Switch in a Network with a DHCP Server
- Discover a Switch in a Network without a DHCP Server
- Configure the Network Settings on the Administrative System
- Access the Management Interface from a Web Browser
- Understand the User Interfaces
- Interface Naming Convention
- Configuring Interface Settings
- Online Help
- Registration
- 2. Configure System Information
- 3. Configuring Switching
- 4. Configuring Routing
- 5. Configuring Quality of Service
- 6. Managing Device Security
- 7. Maintenance
- 8. Monitoring the System
- A. Configuration Examples
- B. Hardware Specifications and Default Values
Maintenance
309
S3300 Smart Managed Pro Switch
Figure 113. Traceroute IPv4
2. Use IP Address/Hostname to enter the IP address or Hostname of the station you want the
switch to discover a path. The default value is blank. The IP Address or Hostname you enter
is not retained across a power cycle.
3. Ente
r the number of Probes Per Hop, the number of times each hop should be probed. The
default value is 3. The range is 1 to 10. The Probes per Hop you enter is not retained across
a power cycle.
4. Ente
r the Maximum TTL, the maximum time-to-live for a packet in the number of hops for
the destination. The default value is 30. The range is 1 to 255. The MaxTTL you enter is not
retained across a power cycle.
5. Ente
r the Initial TTL the initial time-to-live for a packet in the number of hops. The default
value is 1. The range is 1 to 255.The InitTTL you enter is not retained across a power cycle.
6. Ente
r the Maximum Failures allowed in the session. The default value is 5. The range is 1
to 255. The MaxFail you enter is not retained across a power cycle.
7. Interval
(secs) - Enter the number of seconds between probes. The default value is 3. The
range is 1 to 60. The Interval you enter is not retained across a power cycle.
8. Ente
r the UDP Destination Port in the probe packets. The default value is 33434. The range
is 1- 65535. The port you enter is not retained across a power cycle.
9. Ente
r the Size of the probe packets. The default value is 0. The range is 0 to 39936. The
Size you enter is not retained across a power cycle.
10. Ente
r the Source IP address or interface to use when sending the echo request packets. If
source is not required, select None as the source option. Possible values are:
• None — The source is the IP address of the default outgoing interface.