User Manual

Table Of Contents
Configuring Switching
206
S3300 Smart Managed Pro Switch
8. In the Announce Interval field, specify the desired transmission rate of ANNOUNCE
messages.
This value is the logarithm to the base 2 of the mean time interval between successive
ANNOUNCE messages sent on this interface. The configured initial interval becomes the
current interval only after the port is initialized or re-initialized for 802.1AS operation.
9. Configure the SyncRx Timeout.
This value sets the number of SYNC intervals that have to pass without receipt of SYNC
information before considering that the master is no longer transmitting.
10. Configure the AnnounceRx Timeout.
This value sets the number of ANNOUNCE intervals that have to pass without receipt of
ANNOUNCE PDU before considering that the master is no longer transmitting.
11. Click the Apply button.