User Manual
Table Of Contents
- S3300 Smart Managed Pro Switch
- Contents
- 1. Getting Started
- Getting Started with the NETGEAR Switch
- Switch Management Interface
- Connect the Switch to the Network
- Discover a Switch in a Network with a DHCP Server
- Discover a Switch in a Network without a DHCP Server
- Configure the Network Settings on the Administrative System
- Access the Management Interface from a Web Browser
- Understand the User Interfaces
- Interface Naming Convention
- Configuring Interface Settings
- Online Help
- Registration
- 2. Configure System Information
- 3. Configuring Switching
- 4. Configuring Routing
- 5. Configuring Quality of Service
- 6. Managing Device Security
- 7. Maintenance
- 8. Monitoring the System
- A. Configuration Examples
- B. Hardware Specifications and Default Values
Configuring Switching
203
S3300 Smart Managed Pro Switch
The following table shows the non-configurable information on the 802.1AS Configuration
screen.
802.1AS (EAV) in a Stacking Environment
If all the four Uplink ports are configured in Stacking mode, then the EAV pages are disabled
and the 802.1AS (EAV) unavailable message is displayed:
• On th
e Switching > 802.1AS > Basic > 802.1AS Configuration screen as shown in
Figure 89, Switching > 802.1AS (EAV) Unavailable.
Figure 89. Switching > 802.1AS (EAV) Unavailable
• On the Switching > MRP > Basic > MRP Configuration screen as shown in Figure 90,
Switching > MRP > 802.1AS (EAV) Unavailable.
Figure 90. Switching > MRP > 802.1AS (EAV) Unavailable
Table 75. 802.1AS Global Status
Field Description
GrandMaster Present Identifies whether Grand Master Clock is present. The default is False.
Best Clock Identity The Best Clock Identity detected by this time-aware bridge.
Best Clock Priority1 The Priority1 value of the best clock on the switch.
Best Clock Priority2 The Priority2 value of the best clock on the switch.
Steps to Best Clock The number of links in the path from the Best Clock to this time-aware bridge. If
this time-aware bridge is the best, the value is zero.
Local Clock Identity The Clock Identity of this time-aware bridge.
Last GM Change Timestamp The system time when the most recent grandmaster clock change occurred.