Owner's Manual
NMS200 Portlets
74
ProSafe Network Management Software NMS200
Entity Type: Interface, Logical interface
Attribute Description Redcell Email Action variable
Custom 1 Note that although you can re-name
any Custom attribute, you must use
the variable’s original name. For
example here, that is
{RedCell.Config.EquipmentManage
r_Custom1}
{RedCell.Config.Interface_Custom1}
Custom 2 {RedCell.Config.Interface_Custom2}
Custom 3 {RedCell.Config.Interface_Custom3}
Custom 4 {RedCell.Config.Interface_Custom4}
Encapsulation Encapsulation {RedCell.Config.Interface_Encapsulation}
IfIndex SNMP Interface Index {RedCell.Config.Interface_IfIndex}
Interface Description Description of the Interface {RedCell.Config.Interface_DeviceDescription}
Interface Number Interface Number {RedCell.Config.Interface_InterfaceNumber}
Interface Type Common Interface Type {RedCell.Config.Interface_CommonType}
MTU Maximum Transmission Unit {RedCell.Config.Interface_Mtu}
Name Interface name {RedCell.Config.Interface_Name}
Notes Interface Notes {RedCell.Config.Interface_Notes}
Port Number Port Number {RedCell.Config.Interface_PortNumber}
Slot Number Slot Number {RedCell.Config.Interface_SlotNumber}
Subnet Mask Subnet Mask of the Interface {RedCell.Config.Interface_SubMask}
Best practice is to clarify such attributes by combining them with others that spell out their
source.
File Servers
You must configure FTP and/or TFTP file servers to push and pull configuration files to and
from devices, or to deploy firmware updates. With this portlet you can switch between internal
and external file server mode, and Show or Hide not applicable File Servers depending on