M4250 Datasheet
Power Consumption
All ports used, max PoE load, line-rate traffic, maximum
M4250-10G2F-PoE+
M4250-10G2XF-PoE+
M4250-10G2XF-PoE++
M4250-12M2XF
M4250-16XF
163.9W - 559.55 BTU/hr
306.4W - 1046.05 BTU/hr
837.7W - 2859.91 BTU/hr
-
-
All ports used, no PoE, line-rate traffic, maximum
M4250-10G2F-PoE+
M4250-10G2XF-PoE+
M4250-10G2XF-PoE++
M4250-12M2XF
M4250-16XF
17.32W - 59.13 BTU/hr
25W - 85.35 BTU/hr
26.3W - 89.79 BTU/hr
37.9W - 129.39 BTU/hr
47.84W - 163.33 BTU/hr
Standby, no connection on any port
M4250-10G2F-PoE+
M4250-10G2XF-PoE+
M4250-10G2XF-PoE++
M4250-12M2XF
M4250-16XF
8.53W - 29.12BTU/hr
12.96W - 44.24BTU/hr
18W - 61.45BTU/hr
14.1W - 48.14BTU/hr
19.27W - 65.78BTU/hr
Environmental Specications
Operating:
Temperature(non-PoEmodels:
M4250-12M2XF,M4250-16XF)
Temperature(allothermodels)
Humidity
Altitude
32°to122°F(0°to50°C)
32°to113°F(0°to45°C)
90% maximum relative humidity, non-condensing
10,000ft(3,000m)maximum
Storage:
Temperature
Humidity
Altitude
–4°to158°F(–20°to70°C)
95% maximum relative humidity, non-condensing
10,000ft(3,000m)maximum
Electromagnetic Emissions and Immunity
Certications CE:EN55032:2012+AC:2013/CISPR32:2012,EN61000-3-2:2014,
ClassA,EN61000-3-3:2013,EN55024:2010
VCCI:VCCI-CISPR32:2016,ClassA
RCM:AS/NZSCISPR32:2013ClassA
CCC:GB4943.1-2011;YD/T993-1998;GB/T9254-2008(ClassA)
FCC:47CFRFCCPart15,ClassA,ANSIC63.4:2014
ISED:ICES-003:2016Issue6,ClassA,ANSIC63.4:2014
BSMI:CNS13438ClassA
Safety
Certications CBreport/certicateIEC60950-1:2005(ed.2)+A1:2009+A2:2013
ULlisted(UL1950)/cULIEC950/EN60950
CELVD:EN60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
RCM(AS/NZS)60950.1:2015
CCC(ChinaCompulsoryCerticate):GB4943.1-2011;YD/T993-1998;GB/T9254-2008(ClassA)
BSMI:CNS14336-1
PAGE 42 of 44
AV Line Managed Switches
Datasheet | M4250 series
AV Line Managed Switches