M4250 Datasheet
Conditions If ambient temperature
ishigherthan25ºC
and when
39ºC<Sensor≤42ºC
If ambient temperature
ishigherthan25ºCand
when
40ºC<Sensor≤43ºC
Ambient25ºC,Sensor
≤49ºC,PoEPowerLoad
180-720W,
all ports can be used
If ambient temperature
ishigherthan25ºCand
when
61ºC<Sensor≤64ºC
If ambient temperature
ishigherthan25ºCand
when
70ºC<Sensor≤73ºC
Fan duty 75 75 40 75 75
Acoustic noise TBD TBD 47.19dBA TBD TBD
CaseTemperature
(top)
TBD TBD 52.1ºC TBD TBD
Conditions If ambient temperature
ishigherthan25ºC
and when
Sensor>42ºC
If ambient temperature
ishigherthan25ºCand
when
Sensor>43ºC
If ambient temperature
ishigherthan25ºCand
when
49ºC<Sensor≤55ºC
55ºC<Sensor≤60ºC
Sensor>60ºC
If ambient temperature
ishigherthan25ºCand
when
Sensor>64ºC
If ambient temperature
ishigherthan25ºCand
when
Sensor>73ºC
Fan duty 100 100
60
80
100
100 100
Acoustic noise 55dBA 56dBA
TBD
TBD
60dBA
55dBA 57dBA
CaseTemperature
(top)
27.2ºC 30.9ºC
TBD
TBD
41.8ºC
33.2ºC 30.3ºC
Coolmode M4250-10G2F-PoE+ M4250-10G2XF-PoE+ M4250-10G2XF-PoE++ M4250-12M2XF M4250-12M2XF
Fan duty 100 100 100 100 100
Acoustic noise 55dBA 56dBA 60dBA 55dBA 57dBA
CaseTemperature
(top)
27.2ºCwhenambient
25ºC
30.9ºCwhenambient
25ºC
41.8ºCwhenambient
25ºC
33.2ºCwhenambient
25ºC
30.3ºCwhenambient
25ºC
HeatDissipation(BTU) Without PoE, all ports With Max PoE, all ports Standby without any port connection
M4250-10G2F-PoE+ 17.32W - 59.13 BTU/hr 163.9W - 559.55 BTU/hr 8.53W - 29.12BTU/hr
M4250-10G2XF-PoE+ 25W - 85.35 BTU/hr 306.4W - 1046.05 BTU/hr 12.96W - 44.24BTU/hr
M4250-10G2XF-PoE++ 26.3W - 89.79 BTU/hr 837.7W - 2859.91 BTU/hr 18W - 61.45BTU/hr
M4250-12M2XF 37.9W - 129.39 BTU/hr - 14.1W - 48.14BTU/hr
M4250-16XF 47.84W - 163.33 BTU/hr - 19.27W - 65.78BTU/hr
Mean Time Between Failures
(MTBF)
25°Cambient(77°F) @45°Cambient(113°F) @50°Cambient(122°F)
M4250-10G2F-PoE+
778,769 hours
(~88.9years)
530,659 hours
(~60.6years)
-
M4250-10G2XF-PoE+
576,889 hours
(~65.9years)
562,708 hours
(~64.2years)
-
M4250-10G2XF-PoE++
947,871 hours
(~108.2years)
493,860 hours
(~56.4years)
-
M4250-12M2XF
720,892 hours
(~82.3years)
- 416,021hours(~47.5years)
M4250-16XF
844,633 hours
(~96.4years)
- 490,265hours(~56years)
PAGE 24 of 44
AV Line Managed Switches
Datasheet | M4250 series
AV Line Managed Switches