User Manual

Table Of Contents
Maintenance
738
M6100, M5300, and M7100 Series Managed Switches
8. In the IPv6 Address/Hostname field, enter the IPv6 address or host name of the station to
which you want the switch to discover a path.
The initial value is blank. The IPv6 address or host name you enter is not retained across
a power cycle.
9. Enter the Probes Per Hop.
The default value is 3. The range is 1 to 10.
10. Enter the Maximum TTL for the destination.
The default value is 30. The range is 1 to 255. The MaxTTL you enter is not retained
across a power cycle.
11. Enter the Initial TTL to be used.
The default value is 1. The range is 1 to 255. The InitTTL you enter is not retained across
a power cycle.
12. Enter the Maximum Failures allowed in the session.
The default value is 5. The range is 1 to 255. The MaxFail you enter is not retained across
a power cycle.
13. Interval (secs) - Enter the time between probes in seconds.
The default value is 3. The range is 1 to 60. The interval that you enter is not retained
across a power cycle.
14. Enter the UDP Destination Port in probe packets.
The default value is 33434. The range is 1- 65535. The port you enter is not retained
across a power cycle.
15. Enter the Size of the probe packets.