User Manual

Table Of Contents
Maintenance
736
M6100, M5300, and M7100 Series Managed Switches
8. Use IP Address/Hostname to enter the IP address or host name of the station to which you
want to discover a path.
The default value is blank.
9. Enter the number of Probes Per Hop.
The default value is 3. The range is 1 to 10.
10. Enter the Maximum TTL for the destination.
The default value is 30. The range is 1 to 255.
11. Enter the Initial TTL to be used.
The default value is 1. The range is 1 to 255.
12. Enter the Maximum Failures allowed in the session.
The default value is 5. The range is 1 to 255.
13. Interval (secs). Enter the time between probes in seconds.
The default value is 3. The range is 1 to 60.
14. Enter the UDP Destination Port in probe packets.
The default value is 33434. The range is 1- 65535.
15. Enter the Size of the probe packets.
The default value is 0. The range is 0 to 39936.
16. Enter the Source IP address or interface to use when sending the echo request packets.
If source is not required, select None as the source option. Possible values are as
follows:
None. The source address of the ping packet would be the address of the default
outgoing interface.
IP Address. The source IP address to use when sending the echo request packets.
This field is shown when IP Address is selected as the source option.
Interface. The interface to use when sending the echo request packets. This field is
shown when Interface is selected as the source option.
Note: Values configured in the fields in this screen are not saved to the
switch. As a result, refreshing the screen sets these fields to the default
values.
17. Click the Apply button.
A traceroute request is sent to the specified IP address or host name. The results are
displayed below the configurable data in the TraceRoute Results area.
The Results field displays the traceroute IPv4 result after the switch sends a traceroute
request to the specified IP address or host name.