Configure Quality of Service
527
M6100, M5300, and M7100 Series Managed Switches
8. To create a new class, enter a class name, select the class type, and click the Add button.
This field also lists all the existing DiffServ class names, from which one can be selected.
The switch supports only the Class Type value All, which means all the various match
criteria defined for the class is satisfied for a packet match. All signifies the logical AND of
all the match criteria. You can select the class type only when you are creating a new
class. After the class is created, the Class Type field becomes nonconfigurable.
9. To rename an existing class, select the check box next to the configured class, update the
name.
10. Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
11. To remove a class, select the class name check box and click the Delete button.
To refresh the screen with the latest information on the switch, click the Update button.
12. After creating a class, click the class link to the Class screen.
13. Click the class name for an existing class.
The class name is a hyperlink. The following figure shows the configuration fields for the
class.