User Manual

Table Of Contents
Chassis and Stacking
156
M6100, M5300, and M7100 Series Managed Switches
7. Select System > Chassis > Basic > Chassis Configuration.
Note: You can also navigate to this screen by selecting Advanced >
Chassis Configuration.
8. Select the Management Unit.
This field displays the current primary management unit. You can change it by selecting
another blade ID listed here.
9. Click the Apply button to send the updated configuration to the switch.
Configuration changes take effect immediately.
Note: The Move Management operation might cause a change in the system
IP address when the IP address is assigned by a DHCP server.
10. Select the Chassis Sample Mode.
The global status management mode, which can be one of the following:
Cumulative. This tracks the sum of received time-stamp offsets cumulatively.
History. This tracks the history of received timestamps.
11. Enter a value for Max Samples – the maximum number of samples to keep.
The valid range is 100 to 500. Max Samples applies to History mode.
12. Click the Apply button.
The updated configuration is sent to the switch. The mode and sample size parameters
are applied globally to all units in the chassis. Configuration changes take effect
immediately.
13. Select the Unit ID from the displayed list of blades.
14. Specify the Switch Type.
This specifies the type of blade hardware when you are creating a new blade in the
chassis.