Table 7. Device Status (Continued)
DescriptionField
The version of the software for CPLD.CPLD Version
The serial number of this switch.Serial Number
Indicates the status of the power supply in the switch.The status can be
any of the following:
Operational: The power supply is present and functioning properly.
Failed: The power supply is present, but the power cable is not plugged
in or a bad cable is plugged in.
PS-1
Indicates the PoE system status on the switch:
ON: Less than 10W of PoE power is available for another PD.
OFF: At least 10W of PoE power available for another PD.
N/A: PoE is not supported by the switch.
MAX PoE
The time in days, hours, and minutes since the switch was restarted.System Up Time
View the system CPU status
To view the system CPU status:
1. Launch a web browser.
2.
In the address field of your web browser, enter the IP address of the switch.
The login page displays.
3. Click the Main UI Login button.
The main UI login page displays in a new tab.
4. Enter admin as the user name, enter your local device password, and click the Login
button.
The first time that you log in, no password is required. However, you then must
specify a local device password to use each subsequent time that you log in.
The System Information page displays.
5. Select System > Management > System CPU Status.
The System CPU Status page displays.