The power value (in W) that you can enter depends on the physical capacity of the
port (which depends on the switch model) and the selection from the PoE Standard
menu:
•
802.3af: The value that you can enter ranges from 3.0W to 18.0W.
•
Legacy: The value that you can enter ranges from 3.0W to 18.0W.
•
Pre-802.3at: The value that you can enter ranges from 3.0W to 32.0W.
•
802.3at: The value that you can enter ranges from 3.0W to 32.0W.
•
Pre-802.3bt: For PoE++ models, the value that you can enter ranges from 3.0W
to 60.0W.
•
802.3bt-Type3: For PoE++ models, the value that you can enter ranges from
3.0W to 60.0W.
•
802.3bt: For PoE++ models, the value that you can enter ranges from 3.0W to
99.9W.
12.
If you set up one or more PoE schedules (see PoE schedules on page 38), from the
PoE Schedule menu, you can select a schedule.
The default is None, so that no schedule applies.
13. Click the Save button.
Your settings are saved. The window closes. The Power over Ethernet (PoE) page
displays again.
14.
To save the settings to the running configuration, at the top of the page, click the
Save icon or text.
Disable PoE for one or more interfaces
By default, PoE is enabled for all interfaces. You can disable PoE for one or more
interfaces.
To disable PoE for one or more interfaces:
1. Launch a web browser.
2.
In the address field of your web browser, enter the IP address of the switch.
The Login page displays.
3. Enter admin as the user name, enter your local device password, and click the Login
button.
The first time that you log in, no password is required. However, you then must
specify a local device password to use each subsequent time that you log in.
Audio Video User Manual37Power over Ethernet
AV Line of Fully Managed Switches M4250 Series