System information
Chapter 2: Configuring System Information | 59
GS752TXS Smart Switch Software Administration Manual
• Percentage LPI time per Stack - It will get calculated based on the sampling interval
and values fetched during sampling.
• Sample No. - It keeps track of every sample in the table. When the number increases
to maximum it will be rolled over.
• Percentage Time spent in LPI mode since last sample - It will get calculated
based on the sampling interval and values fetched during sampling.
• Percentage Time spent in LPI mode since last reset - It will get calculated based
on the sampling interval and values fetched during sampling.
2. Click Apply to send the updated configuration to the switch. Configuration changes take
effect immediately.
3. Click Refresh to refresh the page with the most current data from the switch.
SNMP
From SNMP link under the System tab, you can configure SNMP settings for SNMP V1/V2
and SNMPv3.
From the SNMP link, you can access the following pages:
• SNMPV1/V2 on page 59
• Trap Flags on page 62
• SNMP v3 User Configuration on page 63
SNMPV1/V2
The pages under the SNMPV1/V2 menu allow you to configure SNMP community
information, traps, and trap flags.
Community Configuration
To display this page, click System SNMP SNMP V1/V2 Community Configuration.
By default, two SNMP Communities exist:
• Private, with Read/Write privileges and status set to Enable.
• Public, with Read Only privileges and status set to Enable.
These are well-known communities. Use this page to change the defaults or to add other
communities. Only the communities that you define using this page will have access to the
switch using the SNMPv1 and SNMPv2c protocols. Only those communities with read/write
level access can be used to change the configuration using SNMP.
Use this page when you are using the SNMPv1 and SNMPv2c protocol.