To display the TACACS+ Server Configuration page, click Security Management Security,
and then click the TACACS+
Server Configuration link.
To configure TACACS+ server settings:
1. To add a new TACACS+ server, select Add from the TACACS+ Server field, enter the
IP address of the server to add, and click Apply.
Note: The Add option is available if fewer than five TACACS+ servers are
configured on the system, and the Server Address field is only
available when Add is selected in the TACACS+ Server IP Address
field.
After you add one or more TACACS+ servers, additional fields appear on the TACACS+
Server Configuration page.
2. In the Priority field, specify the order in which the TACACS+ servers are used. A value of 0
is the highest priority.
3. In the Port field, specify the authentication port number through which the TACACS+
session occurs. The default is port 49, and the range is 0–65535.