Manage Device Security User Manual390
7. Select whether to display physical interfaces, LAGs, or both by clicking one of the following
links above the table heading:
•1 (the unit ID of the switch). Only physical interfaces are displayed.
This is the default
setting.
LAG. Only LAGs are displayed.
All. Both physical interfaces and LAGs are displayed.
8. Select one or more interfaces by taking one of the following actions:
T
o configure a single interface, select the check box associated with the port, or type
the port number in the
Go To Interface field and click the Go button.
To configure multiple interfaces with the same settings, select the check box
associated with each interface.
To configure all interfaces with the same settings, select the check box in the heading
row
.
9. Specify the following settings:
Port Security. Enable or disable the port security feature for the selected interfaces
The default is Disable.
Max Learned MAC Address. Specify the maximum number of dynamically learned
MAC addresses on the selected interfaces.
Max Static MAC Address. Specify the maximum number of statically locked MAC
addresses on the selected interfaces.
Enable Violation Shutdown. Enable or disable shutdown of the selected interfaces if
a packet with a disallowed MAC address is received.
The default value is No, which
means that the option is disabled.
Enable Violation Traps. Enable or disable the sending of new violation traps if a
packet with a disallowed MAC address is received. The default value is No, which
means that the option is disabled.
10. Click the Apply
button.
Your settings are saved.