User Manual

Table Of Contents
24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports
Manage Device Security User Manual356
4. Enter one of the following passwords:
Enter your device admin password.
If you previously managed the switch through the Insight app or Cloud portal, enter
the Insight network password for the last Insight network location.
For information about the credentials, see
Credentials for the device UI on page 30.
5. Click the Go button.
The System Information page displays.
6. Select Security >
Access > HTTP > HTTP Configuration
.
7. Select the Admin Mode Enable or Disable radio button.
This enables or disables HTTP. The default value is Enable.
8. In the HTTP Session Soft Timeout field, specify the number of minutes an HTTP session
can be idle before a time-out occurs.
The value must be in the range of 0–60 minutes.
The default value is 5 minutes. The
currently configured value is shown when the web page is displayed.
After the session is inactive for the configured time, you are automatically logged out and
must reenter the password to access the device UI. A value of zero means that the
session does not time out.
9. In the
HTTP Session Hard Timeout
field, specify the hard time-out for HTTP sessions.
This time-out is unaffected by the activity level of the session. The value must be in the
range of 0–168 hours. value of zero means that the session does not time out. The
default value is 24 hours.
10. In the
Maximum Number of HTTP Sessions field, specify the maximum number of HTTP
sessions that can exist at the same time.
11. Click the Apply button.
Your settings are saved.