7. Select whether to display physical interfaces, LAGs, or both by clicking one of the following
links above the table heading:
•1 (the unit ID of the switch). Only physical interfaces are displayed.
This is the default
setting.
LAG. Only LAGs are displayed.
All. Both physical interfaces and LAGs are displayed.
8. Select one or more interfaces by taking one of the following actions:
T
o configure a single interface, select the check box associated with the port, or type
the port number in the Go To Interface field and click the Go button.
T
o configure multiple interfaces with the same settings, select the check box
associated with each interface.
T
o configure all interfaces with the same settings, select the check box in the heading
row.
9. From the GVRP Mode menu, select Enable or Disable.
This specifies the GARP VLAN registration protocol administrative mode for the port. If
you select Disable, the protocol is not active and the join time, leave time, and leave all
time options are without any ef
fect. The default is Disable.
10. In the Join T
imer field, specify the time in centiseconds between the transmission of GARP
PDUs registering (or reregistering) membership for a VLAN or multicast group.
Enter a number between 10 and 100 (0.1 to 1.0 seconds). The default is 20 centiseconds
(0.2 seconds).
An instance of this timer exists for each GARP participant for each port.
11. In the Leave Timer field, specify the time in centiseconds to wait after receiving an
unregister request for a VLAN or multicast group before deleting the associated entry.
This allows time for another station to assert registration for the same attribute to maintain
uninterrupted service. Enter a number between 20 and 600 (0.2 to 6.0 seconds).
The
default is 60 centiseconds (0.6 seconds). An instance of this timer exists for each GARP
participant for each port.
12. In the Leave All
Timer field, specify how frequently (in centiseconds) LeaveAll PDUs are
generated.
A LeaveAll PDU indicates that all registrations will be deregistered soon. To maintain
registration, participants must rejoin.
The leave all period timer is set to a random value in
the range of LeaveAllTime to 1.5 * LeaveAllTime. The timer is specified in centiseconds.
Enter a number between 200 and 6000 (2 to 60 seconds). The default is 1000
centiseconds (10 seconds). An instance of this timer exists for each GARP participant for
each port.
13. Click the Apply button.
Your settings are saved.